Lennox 10Y61 Programmed ECM Motor Control Module
Specifications
- Brand: Lennox
- Catalog Number: 10Y61
- Model / Part Number: 46132-104
- Product Type: Programmed ECM Motor Control Module
- ECM Version: 5.0
- Voltage: 115V
- Motor Rating: 3/4 HP
- Application: Furnace blower motor
- UPC: 66255146928
- Gross Weight: 3 lb
Lennox identifies 10Y61 as the catalog number for the 46132-104 Programmed Motor Control.
Replacement & Cross-Reference Part Numbers
- 10Y61
- 46132-104
The 46132-104 number is the Lennox model/part number associated directly with catalog number 10Y61.
Lennox 10Y61 ECM Motor Control Module
The Lennox 10Y61 is a factory-programmed ECM blower motor control module used with select Lennox and Allied Air furnaces.
Unlike a complete blower motor assembly, the 10Y61 is the electronic control module that mounts to the ECM motor. The module controls operation of the variable-speed blower according to the programming required by the furnace.
Parts Town identifies the 10Y61 as an ECM 5.0, 115V, 3/4 HP programmed motor control module.
Compatible Brands
The 10Y61 is associated with equipment from:
- Lennox
- Armstrong Air
- AirEase
- Ducane
- Concord
Allied Air distribution information identifies 10Y61 as a programmed ECM furnace motor control used with AirEase/Ducane equipment.
Compatible Furnace Models
Verified applications include:
- G2D95BT080V16C-1
- G2D95CT080V16C-02
The G2D95BT080V16C-1 application is specifically listed for the 10Y61, while Parts Town's model-specific parts listing identifies 10Y61 for G2D95CT080V16C-02.
Because ECM modules are programmed for specific equipment applications, the furnace model and existing module number should be matched before replacement.
Common Symptoms of a Failed ECM Motor Control Module
- Furnace blower does not start
- Blower operates intermittently
- Blower starts and stops unexpectedly
- Incorrect blower speed
- Blower does not respond to a heating or cooling call
- Motor has proper power but does not operate
- ECM motor tests good but the control module does not operate correctly
The blower motor and furnace controls should be diagnosed before replacing the module, since several electrical problems can produce similar symptoms.
Buy Lennox 10Y61 ECM Motor Control Module in Canada
Buy the Lennox 10Y61 / 46132-104 Programmed ECM Motor Control Module from OemHvacPartsCanada.ca.