Skip to product information
Lennox 10F73 Contactor – 1 Pole, 25 Amp, 24 VAC Coil
$100.00
Sale price
$100.00
Regular price
Product Information
- Part Number: 10F73
- Manufacturer Part Number: 100438-04
- Product Type: Definite Purpose Contactor
- Contact Configuration: SPST Normally Open (1 Pole)
- Amperage Rating: 25 FLA
- Coil Voltage: 24 VAC, 50/60 Hz
- Locked Rotor Amps (LRA): 150 Amps @ 240V
- Product Voltage Rating: 600 Volts Maximum
- Features: With Shunt, Additional Cover
- Product Dimensions: 3.26" W × 2.50" D × 2.00" H
- Gross Weight: 0.5 lb
OEM HVAC Parts Canada ships genuine HVAC replacement parts across Canada, including Calgary, Edmonton, Red Deer, Lethbridge, Fort McMurray, Grande Prairie, Medicine Hat, and communities throughout Alberta, as well as the Greater Toronto Area (Toronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Milton, Burlington, Ajax, Pickering, Whitby, and Oshawa). Whether you're an HVAC technician or a homeowner replacing a worn contactor, we ship OEM parts nationwide.
Common Symptoms of a Failing Contactor
- Homeowners in Calgary, Edmonton, Red Deer, Lethbridge, and throughout Alberta may notice the outdoor air conditioner will not start even though the thermostat is calling for cooling. A failed contactor is one of the most common causes.
- Air conditioning systems across the Greater Toronto Area (Toronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Ajax, Pickering, Whitby, and Oshawa) may produce a loud buzzing or chattering sound when the contactor coil begins to fail.
- During Alberta's hot summer months, pitted or burned contacts can prevent power from reaching the compressor, leaving the outdoor unit completely inoperative.
- Homeowners throughout the Greater Toronto Area may notice the contactor pulling in, but the compressor or condenser fan motor never starts because the electrical contacts have become badly worn.
- Air conditioners in Calgary, Edmonton, and throughout Alberta may repeatedly trip the breaker due to damaged or welded contactor contacts.
- Throughout the Greater Toronto Area, a contactor with worn contacts may cause intermittent cooling, where the air conditioner starts normally one cycle and fails the next.
- If your outdoor unit continues running after the thermostat has been satisfied in Alberta or the Greater Toronto Area, welded contactor contacts may be preventing the unit from shutting off.
- Excessive pitting, insect contamination, corrosion, or carbon buildup inside the contactor can cause unreliable operation for homeowners anywhere in Alberta, the GTA, or across Canada.