Goodman 0130F00435 Two-Stage Furnace Pressure Switch – -0.92 / -1.47" W.C.
Specifications
Part Number: 0130F00435
Brand: Goodman / Amana
Product Type: Two-Stage Furnace Pressure Switch
Pressure Ratings: -0.92" / -1.47" W.C.
Stages: 2 Stage
Application: 96% AFUE Gas Furnace
Furnace Type: Upflow / Horizontal
OEM Replacement: Yes
Replaces
0130F00473
The original 0130F00435 has also been superseded by 0130F00435S.
Furnace Models That Use the 0130F00435
The Goodman 0130F00435 pressure switch is used in select GMEC96 two-stage, multi-speed ECM furnaces, including:
GMEC960603ANAA
GMEC960603BNAC
GMEC960603BNBA
GMEC960603BNBB
Goodman's parts documentation confirms the switch in these GMEC96 applications.
Signs of a Faulty 0130F00435 Pressure Switch
A faulty 0130F00435 pressure switch can prevent the furnace from completing its ignition sequence. Common signs include:
- Inducer motor runs but burners do not ignite
- Pressure switch fault code
- Furnace repeatedly attempts to start
- Pressure switch fails to close
- Furnace operates on one stage but has problems changing stages
- Intermittent heating
- Ignitor does not energize after the inducer starts
A pressure-switch fault does not always mean the switch itself has failed. Venting restrictions, condensate drainage problems, blocked pressure tubing or an inducer problem can also prevent the switch from closing.