Skip to product information
Carrier HC21ZS123 Furnace Draft Inducer Motor – 115V 3000 RPM
$200.00
Sale price
$200.00
Regular price
Specifications
- Part Number: HC21ZS123
- Type: Furnace Draft Inducer Motor
- Voltage: 115V
- Frequency: 60 Hz
- Phase: Single Phase
- Speed: 3000 RPM
- Full Load Amps: 1.52A
- Rotation: Counterclockwise (CCW)
- Motor Design: Shaded Pole
- Capacitor Required: No
- Brands: Carrier, Bryant & Payne
Replaces
- HC21ZE123
- HC21ZE123A
Furnace Models
The HC21ZS123 is used in a number of Carrier, Bryant and Payne furnaces. Known compatible models include:
- 58STX11010012
- 58STA11010012
- 58STA11010022
- 58STA13510016
- 58DLA15510020
- 58DLA13510016
- 58DLX13510022
- PG8JAA066135AAJA
- PG8MAA066110
- PG8MAA066135AAJA
- 310AAV036110AAJA
- 310AAV036110ABJA
- 310AAV036110ACJA
- 310AAV036110ADJA
- 310AAV036110EAJA
- 310AAV048110AAJA
- 310AAV048110ABJA
- 310AAV048110ACJA
- 310AAV048110ADJA
- 310AAV048110EAJA
- 310AAV048135AAJA
- 310AAV048135ABJA
- 310AAV048135ACJA
- 310AAV048135ADJA
- 310AAV048135EAJA
- 310AAV060155AAJA
- 310AAV060155ABJA
- 310AAV060155ACJA
- 310AAV060155ADJA
- 310AAV060155EAJA
- 310AAV066110AAJA
- 310AAV066110ABJA
- 310AAV066110ACJA
- 310AAV066110ADJA
- 310AAV066135AAJA
- 310AAV066135ABJA
- 310AAV066135ACJA
- 310AAV066135ADJA
- 310AAV066135EAJA
- 310JAV036110AAJA
- 310JAV036110ABJA
- 310JAV036110ACJA
- 310JAV036110ADJA
- 310JAV036110EAJA
- 310JAV048110AAJA
- 310JAV048110ABJA
- 310JAV048110ACJA
- 310JAV048110ADJA
- 310JAV048110EAJA
- 310JAV048135AAJA
- 310JAV048135ABJA
- 310JAV048135ACJA
- 310JAV048135ADJA
- 310JAV048135EAJA
Symptoms of a Failing Inducer Motor
- Inducer motor does not start when the thermostat calls for heat.
- Furnace will not ignite because the pressure switch does not close.
- Humming or buzzing from the inducer motor.
- Grinding or squealing noises caused by worn motor bearings.
- Rattling or excessive vibration while the inducer is running.
- Pressure switch error codes caused by the inducer not producing enough draft.
- Intermittent operation where the motor sometimes starts and sometimes does not.
- Furnace goes into ignition lockout after repeated failed attempts to start.
- No heat even though the furnace has power.
A pressure-switch error does not automatically mean the inducer motor has failed. Furnace venting, pressure-switch tubing, the pressure switch and other related components should also be checked.
Buy in Canada
Buy the Carrier HC21ZS123 Furnace Draft Inducer Motor at OemHvacPartsCanada.ca.