Lennox 24W97 / 101231-01 Furnace Pressure Switch – 0.40" W.C.
Specifications
Catalog Number: 24W97
Part Number: 101231-01
Brand: Lennox
Product Type: Furnace Pressure Switch
Pressure Setting: 0.40" W.C.
Switch Configuration: SPST Normally Open
Contact Rating: 5A Resistive at 24 VAC
Manufacturer: Microtechnologies
Manufacturer Number: 9370VO-HS-0045
Application: Gas Furnace
OEM Replacement: Yes
Furnace Models That Use the 24W97
The Lennox 24W97 / 101231-01 pressure switch is used in select Lennox G40UH and G50UH furnaces, including:
G40UH-24A-045-15
G40UH-24A-045-17
G40UH-36B-090-15
G40UH-36B-090-16
G40UH-36C-110-15
G40UH-48B-090-17
G40UH-48C-135-15
G40UH-60C-110X-15
G40UH-60D-135-16
G40UH-60D-155-15
G50UH-36B-090-15
G50UH-48B-090X-15
G50UH-48C-110-15
G50UH-48C-135-15
Signs of a Faulty 24W97 Pressure Switch
A faulty 24W97 pressure switch can prevent the furnace from continuing through the ignition sequence. Common symptoms include:
- Inducer motor starts but the ignitor does not energize
- Burners will not ignite
- Furnace displays a pressure-switch fault
- Furnace repeatedly attempts to start
- Pressure switch does not close when proper draft is present
- Intermittent furnace operation
A pressure-switch fault does not automatically mean the 24W97 has failed. Blocked venting, restricted pressure tubing, condensate problems or an inducer motor problem can also prevent the switch from closing.