ICP 1013102 Manual Reset Flame Rollout Limit Switch

ICP 1013102 Manual Reset Flame Rollout Limit Switch

$55.00
Sale price  $55.00 Regular price 
Skip to product information
ICP 1013102 Manual Reset Flame Rollout Limit Switch

ICP 1013102 Manual Reset Flame Rollout Limit Switch

$55.00
Sale price  $55.00 Regular price 

Specifications

  • Part Number: 1013102
  • Manufacturer: International Comfort Products (ICP)
  • Product Type: Flame Rollout Limit Switch
  • Reset Type: Manual Reset
  • Circuit: Normally Closed
  • Opening Temperature: 300°F
  • Application: Gas furnaces and select packaged units

The ICP service documentation confirms that 1013102 opens at 300°F and requires manual reset.

Replacement & Cross-Reference Part Numbers

  • 1013102
  • 1005549
  • 1150544
  • 1320439
  • 300-M
  • 36TX16
  • 6796
  • L300F
  • A1320

ICP 1013102 Flame Rollout Switch

The ICP 1013102 is a 300°F manual-reset flame rollout safety switch used on many International Comfort Products furnaces.

During normal operation the switch remains closed. If excessive heat or flame rollout reaches the switch, it opens the safety circuit and shuts down furnace operation. Because this is a manual-reset switch, it does not automatically reset after cooling.

A tripped rollout switch should not simply be reset repeatedly. The cause of the excessive temperature or flame rollout should be determined before returning the furnace to operation. ICP's own service documentation specifically states that when the switch opens within its specified range, the cause of the over-temperature condition must be corrected.

Compatible Brands

Part 1013102 is used across several ICP-family brands, including:

  • ICP
  • KeepRite
  • Heil
  • Tempstar
  • Comfortmaker
  • Arcoaire

It is used on both furnaces and certain packaged units.

Compatible Furnace Models

Documented applications include:

  • C8DNL050B12A1
  • C8DNL050B12B1
  • C8DNL050B12B2
  • C8DNL075B12A1
  • C8DNL075B12B1
  • C8DNL075F16B1
  • C8DNL100F14A1
  • C8DNL100L20B1
  • C8MPL050B12A1
  • C8MPL075B12B1
  • C8MPL100F20A1
  • C8MPL100J20A1
  • C8MPL125J20A1
  • C8MPN050B12A1
  • C8MPN075B12A1
  • C8MPN100F14A1
  • C8MPN100F20A1
  • C8MPN100J20A1
  • C8MPN125J20A1
  • C8MPN150J20A1
  • C8MPT050B12A1
  • C8MPT075F14A1
  • C8MPT100F14A1
  • C8MPT100J20A1
  • C8MPT125J20A1
  • C8MPV050B12A1
  • C8MPV075F14A1
  • C8MPV100J20A1
  • H8MPN100F14A1
  • H8MPV125J20A1
  • H9MPV100J20A1
  • C9MPD050F12B1
  • C9MPD075F12A1
  • C9MPD080J16B1
  • C9MPD100J14A1
  • N9MP1125J20C2

Additional ICP furnace and packaged-unit models also use this switch, so the furnace model and original part number should be confirmed when selecting a replacement.

Common Signs of a Tripped or Failed Rollout Switch

  • Furnace will not ignite
  • Burners shut down
  • Furnace enters safety lockout
  • No continuity through the rollout switch
  • Manual-reset button has tripped
  • Furnace operates after reset but trips again

Repeated rollout-switch trips can indicate a combustion, venting, heat-exchanger or burner problem and should be investigated rather than bypassing the switch.

Buy ICP 1013102 Rollout Switch in Canada

Buy the ICP 1013102 300°F Manual Reset Flame Rollout Limit Switch from OemHvacPartsCanada.ca.

You may also like