{"product_id":"rheem-42-105499-08k-low-fire-pressure-switch-0-30-wc","title":"Rheem 42-105499-08K Low Fire Pressure Switch (-0.30\" WC)","description":"\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"68\" data-end=\"85\" class=\"PDq2pG_selectionAnchorContainer\"\u003eSpecifications\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"87\" data-end=\"511\"\u003e\n\u003cli data-section-id=\"z6dexv\" data-start=\"87\" data-end=\"119\"\u003e\n\u003cstrong data-start=\"89\" data-end=\"105\"\u003ePart Number:\u003c\/strong\u003e 42-105499-08K\u003c\/li\u003e\n\u003cli data-section-id=\"15fxh49\" data-start=\"120\" data-end=\"146\"\u003e\n\u003cstrong data-start=\"122\" data-end=\"132\"\u003eBrand:\u003c\/strong\u003e Rheem PROTECH\u003c\/li\u003e\n\u003cli data-section-id=\"1s63a3e\" data-start=\"147\" data-end=\"191\"\u003e\n\u003cstrong data-start=\"149\" data-end=\"166\"\u003eProduct Type:\u003c\/strong\u003e Low Fire Pressure Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1o37v86\" data-start=\"192\" data-end=\"224\"\u003e\n\u003cstrong data-start=\"194\" data-end=\"214\"\u003ePressure Rating:\u003c\/strong\u003e -0.30\" WC\u003c\/li\u003e\n\u003cli data-section-id=\"cfr1u6\" data-start=\"225\" data-end=\"277\"\u003e\n\u003cstrong data-start=\"227\" data-end=\"243\"\u003eApplication:\u003c\/strong\u003e Two-Stage Gas Furnaces (Low Fire)\u003c\/li\u003e\n\u003cli data-section-id=\"1behi51\" data-start=\"278\" data-end=\"351\"\u003e\n\u003cstrong data-start=\"280\" data-end=\"293\"\u003eFunction:\u003c\/strong\u003e Monitors inducer draft during the low-fire heating cycle.\u003c\/li\u003e\n\u003cli data-section-id=\"19tbdbx\" data-start=\"352\" data-end=\"386\"\u003e\u003cstrong data-start=\"354\" data-end=\"386\"\u003eGenuine OEM Replacement Part\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"u8r0sg\" data-start=\"387\" data-end=\"511\"\u003e\n\u003cstrong data-start=\"389\" data-end=\"406\"\u003eKit Includes:\u003c\/strong\u003e Pressure switch, mounting hardware, and installation instructions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"8udwcf\" data-start=\"513\" data-end=\"556\"\u003eSome Compatible Rheem Furnace Models Include\u003c\/h3\u003e\n\u003cul data-start=\"558\" data-end=\"701\"\u003e\n\u003cli data-section-id=\"2ytxu6\" data-start=\"558\" data-end=\"575\"\u003eR96TA0602317MSA\u003c\/li\u003e\n\u003cli data-section-id=\"1n40sun\" data-start=\"576\" data-end=\"593\"\u003eR96TA0702317MSA\u003c\/li\u003e\n\u003cli data-section-id=\"1tkhnja\" data-start=\"594\" data-end=\"611\"\u003eR96TA0852521MSA\u003c\/li\u003e\n\u003cli data-section-id=\"1qf08dm\" data-start=\"612\" data-end=\"629\"\u003eR96TA1002521MSA\u003c\/li\u003e\n\u003cli data-section-id=\"w2pwss\" data-start=\"630\" data-end=\"647\"\u003eR96VA0602317MSA\u003c\/li\u003e\n\u003cli data-section-id=\"h6spu5\" data-start=\"648\" data-end=\"665\"\u003eR96VA0702317MSA\u003c\/li\u003e\n\u003cli data-section-id=\"1jr93xj\" data-start=\"666\" data-end=\"683\"\u003eR96VA0852521MSB\u003c\/li\u003e\n\u003cli data-section-id=\"1glrors\" data-start=\"684\" data-end=\"701\"\u003eR96VA1002521MSA\u003cem data-start=\"703\" data-end=\"792\"\u003e\u003c\/em\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"832\" data-end=\"835\"\u003e\n\u003ch2 data-section-id=\"1lf13da\" data-start=\"837\" data-end=\"921\"\u003eCommon Symptoms of a Failing Rheem 42-105499-08 Low Fire Pressure Switch\u003c\/h2\u003e\n\u003cp data-start=\"923\" data-end=\"1400\"\u003eIf your \u003cstrong data-start=\"931\" data-end=\"940\"\u003eRheem\u003c\/strong\u003e or \u003cstrong data-start=\"944\" data-end=\"952\"\u003eRuud\u003c\/strong\u003e two-stage gas furnace in \u003cstrong data-start=\"978\" data-end=\"1035\"\u003eCalgary, Edmonton, Red Deer, Lethbridge, Medicine Hat\u003c\/strong\u003e, or anywhere in \u003cstrong data-start=\"1052\" data-end=\"1063\"\u003eAlberta\u003c\/strong\u003e, or throughout the \u003cstrong data-start=\"1083\" data-end=\"1107\"\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong data-start=\"1119\" data-end=\"1245\"\u003eToronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa\u003c\/strong\u003e, will not complete its heating cycle, a faulty \u003cstrong data-start=\"1293\" data-end=\"1335\"\u003e42-105499-08K Low Fire Pressure Switch\u003c\/strong\u003e may be preventing the furnace from proving proper inducer draft.\u003c\/p\u003e\n\u003cp data-start=\"1812\" data-end=\"1836\"\u003eCommon symptoms include:\u003c\/p\u003e\n\u003cul data-start=\"1838\" data-end=\"2423\"\u003e\n\u003cli data-section-id=\"gaby9j\" data-start=\"1838\" data-end=\"1891\"\u003eInducer motor starts, but the burners never ignite.\u003c\/li\u003e\n\u003cli data-section-id=\"6ntro\" data-start=\"1892\" data-end=\"1950\"\u003eFurnace repeatedly attempts to start before locking out.\u003c\/li\u003e\n\u003cli data-section-id=\"2at2o7\" data-start=\"1951\" data-end=\"2001\"\u003ePressure switch fault or diagnostic error codes.\u003c\/li\u003e\n\u003cli data-section-id=\"tib1c5\" data-start=\"2002\" data-end=\"2074\"\u003eFurnace operates intermittently, especially during low-fire operation.\u003c\/li\u003e\n\u003cli data-section-id=\"f0s33m\" data-start=\"2075\" data-end=\"2158\"\u003eIgnition sequence stops before the hot surface ignitor or gas valve is energized.\u003c\/li\u003e\n\u003cli data-section-id=\"1h4ggyx\" data-start=\"2159\" data-end=\"2224\"\u003eHeat works occasionally but fails on subsequent calls for heat.\u003c\/li\u003e\n\u003cli data-section-id=\"d78jw\" data-start=\"2225\" data-end=\"2299\"\u003eClicking from the pressure switch without completing the ignition cycle.\u003c\/li\u003e\n\u003cli data-section-id=\"1hrbyci\" data-start=\"2300\" data-end=\"2341\"\u003eFurnace locks out until power is reset.\u003c\/li\u003e\n\u003cli data-section-id=\"1q91hy5\" data-start=\"2342\" data-end=\"2423\"\u003ePressure switch fails continuity testing even when the proper draft is present.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53284531962132,"sku":null,"price":60.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem42-105499-08.jpg?v=1785200390","url":"https:\/\/oemhvacpartscanada.ca\/products\/rheem-42-105499-08k-low-fire-pressure-switch-0-30-wc","provider":"Oem Hvac Parts Canada","version":"1.0","type":"link"}