{"product_id":"lennox-48j10-48j1001-blower-motor-3-4-hp-460v-1075-rpm","title":"Lennox 48J10 48J1001 Blower Motor – 3\/4 HP 460V 1075 RPM","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e 48J10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 48J1001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Lennox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Number:\u003c\/strong\u003e K55HXPHL-5118\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Furnace \/ HVAC Blower Motor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorsepower:\u003c\/strong\u003e 3\/4 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 460 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed:\u003c\/strong\u003e 1075 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeeds:\u003c\/strong\u003e 3 Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Type:\u003c\/strong\u003e PSC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e 48\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotation:\u003c\/strong\u003e CCW from Lead End\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e Hub Rings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft Size:\u003c\/strong\u003e 1\/2 in. x 2.5 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitor:\u003c\/strong\u003e 20 MFD \/ 370 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBearing Type:\u003c\/strong\u003e Sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese specifications are directly confirmed by Lennox for 48J10\/48J1001. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eReplacement \u0026amp; Cross-Reference Part Numbers\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLennox 48J10 \/ 48J1001\u003c\/strong\u003e cross-references with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e48J10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48J1001\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eK55HXPHL-5118\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eK55HXPHL5118\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eK055PHL5118011J\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e7A010\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eD15C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e156060\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eD15482979\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe important SEO numbers here are \u003cstrong\u003e48J10, 48J1001 and K55HXPHL-5118\u003c\/strong\u003e. Lennox itself identifies K55HXPHL-5118 with this motor. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eLennox 48J10 Blower Motor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLennox 48J10\u003c\/strong\u003e, part number \u003cstrong\u003e48J1001\u003c\/strong\u003e, is a 3\/4 HP PSC blower motor used in select Lennox HVAC equipment.\u003c\/p\u003e\n\u003cp\u003eThis motor operates on \u003cstrong\u003e460V single-phase power\u003c\/strong\u003e, runs at \u003cstrong\u003e1075 RPM\u003c\/strong\u003e and provides \u003cstrong\u003e3-speed operation\u003c\/strong\u003e. The motor is also identified by motor number \u003cstrong\u003eK55HXPHL-5118\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompatible Lennox Models\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e48J10 \/ 48J1001\u003c\/strong\u003e is used in select Lennox equipment including:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCB29M Series\u003c\/strong\u003e\u003cbr\u003eCB29M-65-1, CB29M-65-2, CB29M-65-3, CB29M-65-4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCHA Series\u003c\/strong\u003e\u003cbr\u003eCHA24-650-1, CHA24-651-1, CHA24-653-1, CHA24D-651-1, CHA24D-653-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCHP Series\u003c\/strong\u003e\u003cbr\u003eCHP20-048-4, CHP20-048-5, CHP20-060-4, CHP20-060-5, CHP24-650-1, CHP24D-651-1, CHP24D-653-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGCS Series\u003c\/strong\u003e\u003cbr\u003eGCS16-048-120-6, GCS16-048-75-6, GCS16-060-120-5, GCS16-060-75-5, GCS20-048-120-6, GCS20-048-120-7, GCS20-048-75-6, GCS20-048-75-7, GCS20-060-120-6, GCS20-060-120-7, GCS20-060-75-6, GCS20-060-75-7\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLCA Series\u003c\/strong\u003e\u003cbr\u003eLCA036H-1, LCA036H4-1, LCA036S-1, LCA042H-1, LCA042S-1, LCA048H-1, LCA048H-3, LCA048H4-3, LCA048S-1, LCA060H-1, LCA060H4-4, LCA060H4-5, LCA060S-1, LCA072H-1, LCA072H4-1, LCA072S-1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLGA Series\u003c\/strong\u003e\u003cbr\u003eLGA036H-1, LGA036H-2, LGA036H4-2, LGA036S-1, LGA036S-2, LGA042H-1, LGA042H-2, LGA042S-1, LGA042S-2, LGA048H-1, LGA048H-2, LGA048H-3, LGA048H4-3, LGA048S-1, LGA048S-2, LGA060H-1, LGA060H-2, LGA060H4-4, LGA060H4-5, LGA060S-1, LGA060S-2, LGA072H-1, LGA072H-2, LGA072H4-2, LGA072S-1, LGA072S-2\u003c\/p\u003e\n\u003cp\u003eThese model applications are documented for 48J10\/48J1001. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Symptoms of a Failed Blower Motor\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBlower motor will not start\u003c\/li\u003e\n\u003cli\u003eMotor runs intermittently\u003c\/li\u003e\n\u003cli\u003eBlower operates at the wrong speed\u003c\/li\u003e\n\u003cli\u003eMotor overheats and shuts off\u003c\/li\u003e\n\u003cli\u003eGrinding or bearing noise\u003c\/li\u003e\n\u003cli\u003eReduced airflow\u003c\/li\u003e\n\u003cli\u003eBlower wheel does not reach proper speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy Lennox 48J10 Blower Motor in Canada\u003c\/h2\u003e\n\u003cp\u003eBuy the \u003cstrong\u003eLennox 48J10 \/ 48J1001 3\/4 HP 460V 1075 RPM Blower Motor\u003c\/strong\u003e from \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53717685207316,"sku":null,"price":600.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem48J1001.jpg?v=1787683376","url":"https:\/\/oemhvacpartscanada.ca\/products\/lennox-48j10-48j1001-blower-motor-3-4-hp-460v-1075-rpm","provider":"Oem Hvac Parts Canada","version":"1.0","type":"link"}