{"product_id":"lennox-28g16-blower-motor-1-2-hp-460v-1075-rpm-3-speed-motor","title":"Lennox 28G16 Blower Motor – 1\/2 HP, 460V, 1075 RPM, 3-Speed Motor","description":"\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"83\" data-end=\"100\" class=\"PDq2pG_selectionAnchorContainer\"\u003eSpecifications\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"102\" data-end=\"662\"\u003e\n\u003cli data-section-id=\"1i5qrkc\" data-start=\"102\" data-end=\"126\"\u003e\n\u003cstrong data-start=\"104\" data-end=\"120\"\u003ePart Number:\u003c\/strong\u003e 28G16\u003c\/li\u003e\n\u003cli data-section-id=\"1ymosc5\" data-start=\"127\" data-end=\"154\"\u003e\n\u003cstrong data-start=\"129\" data-end=\"146\"\u003eModel Number:\u003c\/strong\u003e 28G1601\u003c\/li\u003e\n\u003cli data-section-id=\"1wxntfb\" data-start=\"155\" data-end=\"174\"\u003e\n\u003cstrong data-start=\"157\" data-end=\"167\"\u003eBrand:\u003c\/strong\u003e Lennox\u003c\/li\u003e\n\u003cli data-section-id=\"nd41nj\" data-start=\"175\" data-end=\"218\"\u003e\n\u003cstrong data-start=\"177\" data-end=\"194\"\u003eProduct Type:\u003c\/strong\u003e OEM Supply Blower Motor\u003c\/li\u003e\n\u003cli data-section-id=\"5hzkm2\" data-start=\"219\" data-end=\"243\"\u003e\n\u003cstrong data-start=\"221\" data-end=\"236\"\u003eHorsepower:\u003c\/strong\u003e 1\/2 HP\u003c\/li\u003e\n\u003cli data-section-id=\"wt78nq\" data-start=\"244\" data-end=\"266\"\u003e\n\u003cstrong data-start=\"246\" data-end=\"258\"\u003eVoltage:\u003c\/strong\u003e 460 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"ku7isg\" data-start=\"267\" data-end=\"299\"\u003e\n\u003cstrong data-start=\"269\" data-end=\"279\"\u003ePhase:\u003c\/strong\u003e Single Phase (1 PH)\u003c\/li\u003e\n\u003cli data-section-id=\"g5e3gi\" data-start=\"300\" data-end=\"322\"\u003e\n\u003cstrong data-start=\"302\" data-end=\"316\"\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"h9grgh\" data-start=\"323\" data-end=\"344\"\u003e\n\u003cstrong data-start=\"325\" data-end=\"340\"\u003eMotor Type:\u003c\/strong\u003e PSC\u003c\/li\u003e\n\u003cli data-section-id=\"13qmi5b\" data-start=\"345\" data-end=\"366\"\u003e\n\u003cstrong data-start=\"347\" data-end=\"358\"\u003eSpeeds:\u003c\/strong\u003e 3-Speed\u003c\/li\u003e\n\u003cli data-section-id=\"kh7sse\" data-start=\"367\" data-end=\"382\"\u003e\n\u003cstrong data-start=\"369\" data-end=\"377\"\u003eRPM:\u003c\/strong\u003e 1075\u003c\/li\u003e\n\u003cli data-section-id=\"1q1e47v\" data-start=\"383\" data-end=\"409\"\u003e\n\u003cstrong data-start=\"385\" data-end=\"400\"\u003eFrame Size:\u003c\/strong\u003e 48 Frame\u003c\/li\u003e\n\u003cli data-section-id=\"4ev766\" data-start=\"410\" data-end=\"460\"\u003e\n\u003cstrong data-start=\"412\" data-end=\"425\"\u003eRotation:\u003c\/strong\u003e CCWLE (Counter Clockwise Lead End)\u003c\/li\u003e\n\u003cli data-section-id=\"53bs45\" data-start=\"461\" data-end=\"496\"\u003e\n\u003cstrong data-start=\"463\" data-end=\"480\"\u003eBearing Type:\u003c\/strong\u003e Sleeve Bearings\u003c\/li\u003e\n\u003cli data-section-id=\"1eybk49\" data-start=\"497\" data-end=\"536\"\u003e\n\u003cstrong data-start=\"499\" data-end=\"515\"\u003eMotor Mount:\u003c\/strong\u003e Torsion Flex Bracket\u003c\/li\u003e\n\u003cli data-section-id=\"z09988\" data-start=\"537\" data-end=\"572\"\u003e\n\u003cstrong data-start=\"539\" data-end=\"561\"\u003eMounting Position:\u003c\/strong\u003e Horizontal\u003c\/li\u003e\n\u003cli data-section-id=\"3nu54y\" data-start=\"573\" data-end=\"602\"\u003e\n\u003cstrong data-start=\"575\" data-end=\"590\"\u003eShaft Size:\u003c\/strong\u003e 1\/2\" x 2.5\"\u003c\/li\u003e\n\u003cli data-section-id=\"1du4x93\" data-start=\"603\" data-end=\"625\"\u003e\n\u003cstrong data-start=\"605\" data-end=\"622\"\u003eShaft Length:\u003c\/strong\u003e 3\"\u003c\/li\u003e\n\u003cli data-section-id=\"1gwe555\" data-start=\"626\" data-end=\"662\"\u003e\n\u003cstrong data-start=\"628\" data-end=\"646\"\u003eRun Capacitor:\u003c\/strong\u003e 10 MFD, 370 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"664\" data-end=\"667\"\u003e\n\u003ch2 data-section-id=\"932y32\" data-start=\"669\" data-end=\"726\"\u003eCommon Symptoms of a Failing Lennox 28G16 Blower Motor\u003c\/h2\u003e\n\u003cp data-start=\"728\" data-end=\"1257\"\u003eA failing \u003cstrong data-start=\"738\" data-end=\"767\"\u003eLennox 28G16 blower motor\u003c\/strong\u003e can significantly reduce airflow and eventually prevent your furnace or air handler from operating properly. Whether you're located in \u003cstrong data-start=\"903\" data-end=\"960\"\u003eCalgary, Edmonton, Red Deer, Lethbridge, Medicine Hat\u003c\/strong\u003e, or elsewhere in \u003cstrong data-start=\"978\" data-end=\"989\"\u003eAlberta\u003c\/strong\u003e, or in the \u003cstrong data-start=\"1001\" data-end=\"1025\"\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong data-start=\"1037\" data-end=\"1163\"\u003eToronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa\u003c\/strong\u003e, homeowners commonly experience the following symptoms when this blower motor begins to fail:\u003c\/p\u003e\n\u003cul data-start=\"1259\" data-end=\"1759\"\u003e\n\u003cli data-section-id=\"18uf8vd\" data-start=\"1259\" data-end=\"1292\"\u003eWeak airflow from supply vents.\u003c\/li\u003e\n\u003cli data-section-id=\"16lhuas\" data-start=\"1293\" data-end=\"1332\"\u003eBlower motor hums but does not start.\u003c\/li\u003e\n\u003cli data-section-id=\"u5t9dd\" data-start=\"1333\" data-end=\"1385\"\u003eFurnace overheats and trips the high-limit switch.\u003c\/li\u003e\n\u003cli data-section-id=\"iwvf1f\" data-start=\"1386\" data-end=\"1451\"\u003eBlower starts intermittently or only after being manually spun.\u003c\/li\u003e\n\u003cli data-section-id=\"yxl2s\" data-start=\"1452\" data-end=\"1507\"\u003eBurning electrical smell coming from the air handler.\u003c\/li\u003e\n\u003cli data-section-id=\"4nmwwf\" data-start=\"1508\" data-end=\"1575\"\u003eExcessive squealing, grinding, or bearing noise during operation.\u003c\/li\u003e\n\u003cli data-section-id=\"4ahuqu\" data-start=\"1576\" data-end=\"1635\"\u003eBlower motor overheats and shuts off on thermal overload.\u003c\/li\u003e\n\u003cli data-section-id=\"1lwtigb\" data-start=\"1636\" data-end=\"1686\"\u003eIndoor comfort decreases due to reduced airflow.\u003c\/li\u003e\n\u003cli data-section-id=\"14pm77a\" data-start=\"1687\" data-end=\"1759\"\u003eCircuit breaker trips because the motor is drawing excessive amperage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1383\" data-end=\"1605\"\u003eFor customers in the \u003cstrong data-start=\"1404\" data-end=\"1428\"\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong data-start=\"1440\" data-end=\"1566\"\u003eToronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa\u003c\/strong\u003e, common blower motor problems include:\u003c\/p\u003e\n\u003cul data-start=\"1607\" data-end=\"1954\"\u003e\n\u003cli data-section-id=\"12twg18\" data-start=\"1899\" data-end=\"1954\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53162125459732,"sku":null,"price":635.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem28G16.jpg?v=1785105779","url":"https:\/\/oemhvacpartscanada.ca\/products\/lennox-28g16-blower-motor-1-2-hp-460v-1075-rpm-3-speed-motor","provider":"Oem Hvac Parts Canada","version":"1.0","type":"link"}