{"title":"Rollout Switch","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eFurnace Rollout Switches\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eShop \u003cstrong\u003efurnace rollout switches\u003c\/strong\u003e for residential gas furnaces and heating equipment. Rollout switches are safety devices designed to shut down the furnace if excessive heat or flame is detected outside the burner area.\u003c\/p\u003e\n\u003cp\u003eOemHvacPartsCanada.ca carries replacement \u003cstrong\u003emanual-reset and automatic-reset rollout switches\u003c\/strong\u003e for many major HVAC brands, including Lennox, Carrier, Bryant, KeepRite, Heil, Tempstar, Goodman, Amana, Rheem, Ruud, York and others.\u003c\/p\u003e\n\u003cp\u003eWhen replacing a rollout switch, always match the \u003cstrong\u003epart number, temperature rating, reset type and furnace application\u003c\/strong\u003e to the original switch.\u003c\/p\u003e\n\u003cp\u003eShop furnace rollout switches and replacement HVAC parts in Canada from\u003ca href=\"https:\/\/oemhvacpartscanada.ca\/pages\/home\"\u003e \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"icp-1013102-manual-reset-flame-rollout-limit-switch","title":"ICP 1013102 Manual Reset Flame Rollout Limit Switch","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1013102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e International Comfort Products (ICP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Flame Rollout Limit Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Type:\u003c\/strong\u003e Manual Reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit:\u003c\/strong\u003e Normally Closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpening Temperature:\u003c\/strong\u003e 300°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas furnaces and select packaged units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ICP service documentation confirms that \u003cstrong\u003e1013102 opens at 300°F and requires manual reset\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eReplacement \u0026amp; Cross-Reference Part Numbers\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1013102\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1005549\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1150544\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1320439\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e300-M\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e36TX16\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e6796\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eL300F\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA1320\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eICP 1013102 Flame Rollout Switch\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eICP 1013102\u003c\/strong\u003e is a 300°F manual-reset flame rollout safety switch used on many International Comfort Products furnaces.\u003c\/p\u003e\n\u003cp\u003eDuring normal operation the switch remains closed. If excessive heat or flame rollout reaches the switch, it opens the safety circuit and shuts down furnace operation. Because this is a \u003cstrong\u003emanual-reset switch\u003c\/strong\u003e, it does not automatically reset after cooling.\u003c\/p\u003e\n\u003cp\u003eA tripped rollout switch should not simply be reset repeatedly. The cause of the excessive temperature or flame rollout should be determined before returning the furnace to operation. ICP's own service documentation specifically states that when the switch opens within its specified range, the cause of the over-temperature condition must be corrected. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cp\u003ePart 1013102 is used across several ICP-family brands, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICP\u003c\/li\u003e\n\u003cli\u003eKeepRite\u003c\/li\u003e\n\u003cli\u003eHeil\u003c\/li\u003e\n\u003cli\u003eTempstar\u003c\/li\u003e\n\u003cli\u003eComfortmaker\u003c\/li\u003e\n\u003cli\u003eArcoaire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is used on both furnaces and certain packaged units. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp\u003eDocumented applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eC8DNL050B12A1\u003c\/li\u003e\n\u003cli\u003eC8DNL050B12B1\u003c\/li\u003e\n\u003cli\u003eC8DNL050B12B2\u003c\/li\u003e\n\u003cli\u003eC8DNL075B12A1\u003c\/li\u003e\n\u003cli\u003eC8DNL075B12B1\u003c\/li\u003e\n\u003cli\u003eC8DNL075F16B1\u003c\/li\u003e\n\u003cli\u003eC8DNL100F14A1\u003c\/li\u003e\n\u003cli\u003eC8DNL100L20B1\u003c\/li\u003e\n\u003cli\u003eC8MPL050B12A1\u003c\/li\u003e\n\u003cli\u003eC8MPL075B12B1\u003c\/li\u003e\n\u003cli\u003eC8MPL100F20A1\u003c\/li\u003e\n\u003cli\u003eC8MPL100J20A1\u003c\/li\u003e\n\u003cli\u003eC8MPL125J20A1\u003c\/li\u003e\n\u003cli\u003eC8MPN050B12A1\u003c\/li\u003e\n\u003cli\u003eC8MPN075B12A1\u003c\/li\u003e\n\u003cli\u003eC8MPN100F14A1\u003c\/li\u003e\n\u003cli\u003eC8MPN100F20A1\u003c\/li\u003e\n\u003cli\u003eC8MPN100J20A1\u003c\/li\u003e\n\u003cli\u003eC8MPN125J20A1\u003c\/li\u003e\n\u003cli\u003eC8MPN150J20A1\u003c\/li\u003e\n\u003cli\u003eC8MPT050B12A1\u003c\/li\u003e\n\u003cli\u003eC8MPT075F14A1\u003c\/li\u003e\n\u003cli\u003eC8MPT100F14A1\u003c\/li\u003e\n\u003cli\u003eC8MPT100J20A1\u003c\/li\u003e\n\u003cli\u003eC8MPT125J20A1\u003c\/li\u003e\n\u003cli\u003eC8MPV050B12A1\u003c\/li\u003e\n\u003cli\u003eC8MPV075F14A1\u003c\/li\u003e\n\u003cli\u003eC8MPV100J20A1\u003c\/li\u003e\n\u003cli\u003eH8MPN100F14A1\u003c\/li\u003e\n\u003cli\u003eH8MPV125J20A1\u003c\/li\u003e\n\u003cli\u003eH9MPV100J20A1\u003c\/li\u003e\n\u003cli\u003eC9MPD050F12B1\u003c\/li\u003e\n\u003cli\u003eC9MPD075F12A1\u003c\/li\u003e\n\u003cli\u003eC9MPD080J16B1\u003c\/li\u003e\n\u003cli\u003eC9MPD100J14A1\u003c\/li\u003e\n\u003cli\u003eN9MP1125J20C2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional ICP furnace and packaged-unit models also use this switch, so the furnace model and original part number should be confirmed when selecting a replacement. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Signs of a Tripped or Failed Rollout Switch\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eBurners shut down\u003c\/li\u003e\n\u003cli\u003eFurnace enters safety lockout\u003c\/li\u003e\n\u003cli\u003eNo continuity through the rollout switch\u003c\/li\u003e\n\u003cli\u003eManual-reset button has tripped\u003c\/li\u003e\n\u003cli\u003eFurnace operates after reset but trips again\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRepeated rollout-switch trips can indicate a combustion, venting, heat-exchanger or burner problem and should be investigated rather than bypassing the switch.\u003c\/p\u003e\n\u003ch2\u003eBuy ICP 1013102 Rollout Switch in Canada\u003c\/h2\u003e\n\u003cp\u003eBuy the \u003cstrong\u003eICP 1013102 300°F Manual Reset Flame \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/collections\/rollout-switch\"\u003eRollout Limit Switch\u003c\/a\u003e\u003c\/strong\u003e from \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003e\u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/a\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53736583037204,"sku":null,"price":55.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem1013102.jpg?v=1787963880"},{"product_id":"lennox-78l29-78l2901-flame-rollout-switch","title":"Lennox 78L29 \/ 78L2901 Flame Rollout Switch","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Lennox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e 78L29\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e 78L2901\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Flame Rollout Limit Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Type:\u003c\/strong\u003e Manual Reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuation Temperature:\u003c\/strong\u003e 250°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Type:\u003c\/strong\u003e SPST\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour Identification:\u003c\/strong\u003e Blue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 66255135674\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas furnace safety control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLennox identifies the \u003cstrong\u003e78L29 \/ 78L2901\u003c\/strong\u003e as a manual-reset rollout switch that actuates at \u003cstrong\u003e250°F\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eReplacement \u0026amp; Cross-Reference Part Numbers\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e78L29\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78L2901\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe catalog number \u003cstrong\u003e78L29\u003c\/strong\u003e and model\/part number \u003cstrong\u003e78L2901\u003c\/strong\u003e identify the same Lennox rollout control. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eLennox 78L29 Flame Rollout Switch\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLennox 78L29\u003c\/strong\u003e is a manual-reset furnace safety switch designed to open the safety circuit if excessive heat or flame rollout is detected in the burner area.\u003c\/p\u003e\n\u003cp\u003eThe switch is normally part of the furnace safety circuit. If the temperature at the switch reaches approximately \u003cstrong\u003e250°F\u003c\/strong\u003e, the switch opens and interrupts furnace operation.\u003c\/p\u003e\n\u003cp\u003eBecause the 78L29 is a \u003cstrong\u003emanual-reset rollout switch\u003c\/strong\u003e, a tripped switch should not simply be repeatedly reset. The furnace should be inspected to determine why the rollout switch opened.\u003c\/p\u003e\n\u003ch2\u003eCompatible Lennox Furnace Models\u003c\/h2\u003e\n\u003cp\u003eThe 78L29 is used in numerous Lennox furnace models, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-24A-045\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-24A-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-36A-045\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-36A-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-36B-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-36C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-48B-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-48B-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-48C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG40UH-60C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG43UF-24B-045\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG43UF-24B-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG43UF-36B-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG43UF-36C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG43UF-48C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG43UF-48C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG43UF-60C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG43UF-60D-135\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG50UH-24A-045\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG50UH-24A-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG50UH-36A-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG50UH-36B-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG50UH-36C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG50UH-48B-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG50UH-48B-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG50UH-48C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG50UH-60C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG51MP-24B-045\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG51MP-36B-045\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG51MP-36B-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG51MP-36C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG51MP-48C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG51MP-48C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG51MP-60C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG51MP-60C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG51MP-60D-135\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG60UH-24A-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG60UH-36A-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG60UH-36B-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG60UH-36C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG60UH-48B-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG60UH-48C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG60UH-60C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MP-36B-045\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MP-36B-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MP-48C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MP-48C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MP-60C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MP-60C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MP-60D-135\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MPV-36B-045\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MPV-36B-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MPV-36C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MPV-60C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MPV-60C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG61MPV-60D-135\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG71MPP-36B-070\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG71MPP-36C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG71MPP-60C-090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG71MPP-60C-110\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eG71MPP-60D-135\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese applications are documented for the 78L29 rollout switch. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Signs of a Tripped or Failed Rollout Switch\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eBurners shut down shortly after ignition\u003c\/li\u003e\n\u003cli\u003eFurnace enters safety lockout\u003c\/li\u003e\n\u003cli\u003eNo continuity through the rollout switch\u003c\/li\u003e\n\u003cli\u003eManual-reset button has tripped\u003c\/li\u003e\n\u003cli\u003eFurnace repeatedly shuts down during a heating call\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA rollout switch that repeatedly trips can indicate a combustion, burner, venting or heat-exchanger problem. The cause should be diagnosed rather than bypassing the safety switch.\u003c\/p\u003e\n\u003ch2\u003eBuy Lennox 78L29 Rollout Switch in Canada\u003c\/h2\u003e\n\u003cp\u003eBuy the \u003cstrong\u003eLennox 78L29 \/ 78L2901 250°F Manual Reset \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/collections\/rollout-switch\"\u003eFlame Rollout Switch\u003c\/a\u003e\u003c\/strong\u003e from \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003e\u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/a\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53765622432020,"sku":null,"price":50.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem78L29.jpg?v=1788007326"}],"url":"https:\/\/oemhvacpartscanada.ca\/collections\/rollout-switch.oembed","provider":"Oem Hvac Parts Canada","version":"1.0","type":"link"}