{"title":"Board","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eBuy Your Furnace Control Board from OemHvacPartsCanada.ca\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eLooking for a replacement furnace control board? \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e is a Canadian owned and operated business specializing in genuine OEM HVAC parts. We stock a growing selection of furnace ignition control boards, integrated furnace control boards, and fan control boards for many of Canada's most trusted heating manufacturers.\u003c\/p\u003e\n\u003cp\u003eOur inventory includes genuine OEM furnace control boards for brands such as \u003cstrong\u003eCarrier, Bryant, Payne, Lennox, Rheem, Ruud, Goodman, Amana, York, Coleman, Luxaire, Trane, American Standard, Heil, Tempstar, Comfortmaker, Keeprite, Arcoaire, Day \u0026amp; Night, ICP, Armstrong Air, Ducane, AirEase, Frigidaire, Gibson, Maytag, Westinghouse,\u003c\/strong\u003e and \u003cstrong\u003eNordyne\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eA faulty furnace control board can cause a wide range of heating problems. Your furnace may not ignite, the blower may run continuously, the inducer motor may not start, the igniter may not receive power, or the furnace may repeatedly lock out with an error code. Replacing a failed control board with the correct OEM replacement can restore normal furnace operation.\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e, we carry genuine OEM control boards for single-stage, two-stage, and variable-speed furnaces. Whether you're replacing a Lennox, Carrier, Goodman, Rheem, or another manufacturer's control board, we're here to help you find the right part.\u003c\/p\u003e\n\u003cp\u003eBrowse our selection of \u003cstrong\u003eOEM furnace control boards\u003c\/strong\u003e at \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/p\u003e","products":[{"product_id":"carrier-325878-751-oem-furnace-control-board","title":"Carrier 325878-751 OEM Furnace Control Board","description":"\u003ch3 data-section-id=\"1yl5694\" data-start=\"49\" data-end=\"67\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"69\" data-end=\"577\"\u003e\n\u003cli data-section-id=\"4ezrbv\" data-start=\"69\" data-end=\"98\"\u003e\n\u003cstrong data-start=\"71\" data-end=\"87\"\u003ePart Number:\u003c\/strong\u003e 325878-751\u003c\/li\u003e\n\u003cli data-section-id=\"1pb9dm0\" data-start=\"99\" data-end=\"169\"\u003e\n\u003cstrong data-start=\"101\" data-end=\"118\"\u003eProduct Type:\u003c\/strong\u003e OEM Furnace Main Control Board \/ Circuit Board Kit\u003c\/li\u003e\n\u003cli data-section-id=\"2pme1h\" data-start=\"170\" data-end=\"190\"\u003e\n\u003cstrong data-start=\"172\" data-end=\"182\"\u003eBrand:\u003c\/strong\u003e Carrier\u003c\/li\u003e\n\u003cli data-section-id=\"1f8kpgo\" data-start=\"191\" data-end=\"235\"\u003e\n\u003cstrong data-start=\"193\" data-end=\"209\"\u003eApplication:\u003c\/strong\u003e Gas furnace control board\u003c\/li\u003e\n\u003cli data-section-id=\"6yfj1h\" data-start=\"236\" data-end=\"265\"\u003e\n\u003cstrong data-start=\"238\" data-end=\"250\"\u003eVoltage:\u003c\/strong\u003e 24 VAC control\u003c\/li\u003e\n\u003cli data-section-id=\"1r4t1e9\" data-start=\"266\" data-end=\"313\"\u003e\n\u003cstrong data-start=\"268\" data-end=\"290\"\u003eCompatible Brands:\u003c\/strong\u003e Carrier, Bryant, Payne\u003c\/li\u003e\n\u003cli data-section-id=\"18o3biu\" data-start=\"314\" data-end=\"434\"\u003e\n\u003cstrong data-start=\"316\" data-end=\"350\"\u003eReplaces Older Control Boards:\u003c\/strong\u003e\n\u003cul data-start=\"353\" data-end=\"434\"\u003e\n\u003cli data-section-id=\"18teixx\" data-start=\"353\" data-end=\"364\"\u003eHK42FZ004\u003c\/li\u003e\n\u003cli data-section-id=\"18teixy\" data-start=\"367\" data-end=\"378\"\u003eHK42FZ007\u003c\/li\u003e\n\u003cli data-section-id=\"18teiy1\" data-start=\"381\" data-end=\"392\"\u003eHK42FZ008\u003c\/li\u003e\n\u003cli data-section-id=\"18teiy0\" data-start=\"395\" data-end=\"406\"\u003eHK42FZ009\u003c\/li\u003e\n\u003cli data-section-id=\"18teiv5\" data-start=\"409\" data-end=\"420\"\u003eHK42FZ011\u003c\/li\u003e\n\u003cli data-section-id=\"18teiva\" data-start=\"423\" data-end=\"434\"\u003eHK42FZ016\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uyskxk\" data-start=\"435\" data-end=\"577\"\u003e\n\u003cstrong data-start=\"437\" data-end=\"454\"\u003eKit Includes:\u003c\/strong\u003e Updated control board and wiring harness\/plug adapter for compatible furnace models. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"579\" data-end=\"582\"\u003e\n\u003ch2 data-section-id=\"8f8u7h\" data-start=\"584\" data-end=\"647\"\u003eCommon Symptoms of a Failed Carrier 325878-751 Control Board\u003c\/h2\u003e\n\u003cp data-start=\"649\" data-end=\"888\"\u003eA faulty furnace control board can create a variety of intermittent or complete system failures. If your Carrier, Bryant, or Payne furnace is experiencing any of the following problems, the 325878-751 control board may require replacement.\u003c\/p\u003e\n\u003ch3 data-section-id=\"6xs0if\" data-start=\"890\" data-end=\"922\"\u003eAlberta (Calgary \u0026amp; Edmonton)\u003c\/h3\u003e\n\u003cp data-start=\"924\" data-end=\"1009\"\u003eDuring Alberta's cold winters, homeowners in \u003cstrong data-start=\"969\" data-end=\"980\"\u003eCalgary\u003c\/strong\u003e and \u003cstrong data-start=\"985\" data-end=\"997\"\u003eEdmonton\u003c\/strong\u003e may notice:\u003c\/p\u003e\n\u003cul data-start=\"1011\" data-end=\"1267\"\u003e\n\u003cli data-section-id=\"d9uu00\" data-start=\"1011\" data-end=\"1055\"\u003eFurnace completely dead with no operation.\u003c\/li\u003e\n\u003cli data-section-id=\"dmtj1h\" data-start=\"1056\" data-end=\"1087\"\u003eInducer motor fails to start.\u003c\/li\u003e\n\u003cli data-section-id=\"dvgvv0\" data-start=\"1088\" data-end=\"1110\"\u003eIgnitor never glows.\u003c\/li\u003e\n\u003cli data-section-id=\"3qn9yu\" data-start=\"1111\" data-end=\"1144\"\u003eGas valve never receives power.\u003c\/li\u003e\n\u003cli data-section-id=\"55s0mm\" data-start=\"1145\" data-end=\"1208\"\u003eFurnace repeatedly locks out after several ignition attempts.\u003c\/li\u003e\n\u003cli data-section-id=\"65v438\" data-start=\"1209\" data-end=\"1267\"\u003eDiagnostic LED displays fault codes or no lights at all.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1269\" data-end=\"1272\"\u003e\n\u003ch3 data-section-id=\"13vtxfy\" data-start=\"1274\" data-end=\"1360\"\u003eGreater Toronto Area (Toronto, Mississauga, Brampton, Vaughan, Markham \u0026amp; Oakville)\u003c\/h3\u003e\n\u003cp data-start=\"1362\" data-end=\"1538\"\u003eIf you live in the \u003cstrong data-start=\"1381\" data-end=\"1405\"\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong data-start=\"1417\" data-end=\"1428\"\u003eToronto\u003c\/strong\u003e, \u003cstrong data-start=\"1430\" data-end=\"1445\"\u003eMississauga\u003c\/strong\u003e, \u003cstrong data-start=\"1447\" data-end=\"1459\"\u003eBrampton\u003c\/strong\u003e, \u003cstrong data-start=\"1461\" data-end=\"1472\"\u003eVaughan\u003c\/strong\u003e, \u003cstrong data-start=\"1474\" data-end=\"1485\"\u003eMarkham\u003c\/strong\u003e, or \u003cstrong data-start=\"1490\" data-end=\"1502\"\u003eOakville\u003c\/strong\u003e, a failing control board may cause:\u003c\/p\u003e\n\u003cul data-start=\"1540\" data-end=\"1803\"\u003e\n\u003cli data-section-id=\"on6iz0\" data-start=\"1540\" data-end=\"1571\"\u003eBlower fan runs continuously.\u003c\/li\u003e\n\u003cli data-section-id=\"1q7328o\" data-start=\"1572\" data-end=\"1613\"\u003eFurnace cycles on and off unexpectedly.\u003c\/li\u003e\n\u003cli data-section-id=\"17fvjg4\" data-start=\"1614\" data-end=\"1662\"\u003eNo heat even though the thermostat is calling.\u003c\/li\u003e\n\u003cli data-section-id=\"nc1q2u\" data-start=\"1663\" data-end=\"1708\"\u003eBurners ignite briefly before shutting off.\u003c\/li\u003e\n\u003cli data-section-id=\"1c1zuaf\" data-start=\"1709\" data-end=\"1741\"\u003eRandom intermittent operation.\u003c\/li\u003e\n\u003cli data-section-id=\"1ma74fx\" data-start=\"1742\" data-end=\"1803\"\u003eError codes that continue after replacing other components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53161683386644,"sku":null,"price":750.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem325878-751.png?v=1785097359"},{"product_id":"lennox-49w66-furnace-ignition-module-102186-02","title":"Lennox 49W66 Furnace Ignition Module 102186-02","description":"\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"84\" data-end=\"101\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"103\" data-end=\"707\"\u003e\n\u003cli data-section-id=\"1i4a3x8\" data-start=\"103\" data-end=\"127\"\u003e\n\u003cstrong data-start=\"105\" data-end=\"121\"\u003ePart Number:\u003c\/strong\u003e 49W66\u003c\/li\u003e\n\u003cli data-section-id=\"1jjb2n2\" data-start=\"128\" data-end=\"157\"\u003e\n\u003cstrong data-start=\"130\" data-end=\"147\"\u003eModel Number:\u003c\/strong\u003e 102186-01\u003c\/li\u003e\n\u003cli data-section-id=\"1wxntfb\" data-start=\"158\" data-end=\"177\"\u003e\n\u003cstrong data-start=\"160\" data-end=\"170\"\u003eBrand:\u003c\/strong\u003e Lennox\u003c\/li\u003e\n\u003cli data-section-id=\"9jb7ph\" data-start=\"178\" data-end=\"227\"\u003e\n\u003cstrong data-start=\"180\" data-end=\"197\"\u003eProduct Type:\u003c\/strong\u003e Direct Spark Ignition Control\u003c\/li\u003e\n\u003cli data-section-id=\"iexbeq\" data-start=\"228\" data-end=\"252\"\u003e\n\u003cstrong data-start=\"230\" data-end=\"247\"\u003eManufacturer:\u003c\/strong\u003e UTEC\u003c\/li\u003e\n\u003cli data-section-id=\"1f1duxw\" data-start=\"253\" data-end=\"279\"\u003e\n\u003cstrong data-start=\"255\" data-end=\"270\"\u003eUTEC Model:\u003c\/strong\u003e 1016-500\u003c\/li\u003e\n\u003cli data-section-id=\"uv4ar1\" data-start=\"280\" data-end=\"321\"\u003e\n\u003cstrong data-start=\"282\" data-end=\"304\"\u003eOperating Voltage:\u003c\/strong\u003e 24 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"8trd6d\" data-start=\"322\" data-end=\"361\"\u003e\n\u003cstrong data-start=\"324\" data-end=\"346\"\u003eOperating Current:\u003c\/strong\u003e 250 mA Maximum\u003c\/li\u003e\n\u003cli data-section-id=\"1pfplii\" data-start=\"362\" data-end=\"399\"\u003e\n\u003cstrong data-start=\"364\" data-end=\"378\"\u003ePre-Purge:\u003c\/strong\u003e 30 Seconds (Nominal)\u003c\/li\u003e\n\u003cli data-section-id=\"hmstfp\" data-start=\"400\" data-end=\"435\"\u003e\n\u003cstrong data-start=\"402\" data-end=\"425\"\u003eTrial for Ignition:\u003c\/strong\u003e 8 Seconds\u003c\/li\u003e\n\u003cli data-section-id=\"jdk53b\" data-start=\"436\" data-end=\"489\"\u003e\n\u003cstrong data-start=\"438\" data-end=\"458\"\u003eIgnition Trials:\u003c\/strong\u003e 3 Trials with 5-Minute Recycle\u003c\/li\u003e\n\u003cli data-section-id=\"1c3836u\" data-start=\"490\" data-end=\"529\"\u003e\n\u003cstrong data-start=\"492\" data-end=\"514\"\u003eSpark Transformer:\u003c\/strong\u003e Rajah Terminal\u003c\/li\u003e\n\u003cli data-section-id=\"1bdra1t\" data-start=\"530\" data-end=\"573\"\u003e\n\u003cstrong data-start=\"532\" data-end=\"558\"\u003eOperating Temperature:\u003c\/strong\u003e -40°F to 176°F\u003c\/li\u003e\n\u003cli data-section-id=\"yczp9l\" data-start=\"574\" data-end=\"600\"\u003e\n\u003cstrong data-start=\"576\" data-end=\"594\"\u003eHousing Color:\u003c\/strong\u003e Black\u003c\/li\u003e\n\u003cli data-section-id=\"qixa6v\" data-start=\"601\" data-end=\"646\"\u003e\n\u003cstrong data-start=\"603\" data-end=\"618\"\u003eDimensions:\u003c\/strong\u003e 5.18\" H × 4.18\" W × 2.13\" D\u003c\/li\u003e\n\u003cli data-section-id=\"90eum\" data-start=\"647\" data-end=\"707\"\u003e\n\u003cstrong data-start=\"649\" data-end=\"660\"\u003eWeight:\u003c\/strong\u003e 0.75 lbs \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"709\" data-end=\"712\"\u003e\n\u003ch2 data-section-id=\"psape8\" data-start=\"714\" data-end=\"788\"\u003eCommon Symptoms of a Failing Lennox 49W66 Direct Spark Ignition Control\u003c\/h2\u003e\n\u003cp data-start=\"790\" data-end=\"1285\"\u003eA failing \u003cstrong data-start=\"800\" data-end=\"846\"\u003eLennox 49W66 Direct Spark Ignition Control\u003c\/strong\u003e can prevent your furnace from completing the ignition sequence, leaving your home without heat. Whether you're located in \u003cstrong data-start=\"969\" data-end=\"1026\"\u003eCalgary, Edmonton, Red Deer, Lethbridge, Medicine Hat\u003c\/strong\u003e, or elsewhere in \u003cstrong data-start=\"1044\" data-end=\"1055\"\u003eAlberta\u003c\/strong\u003e, or in the \u003cstrong data-start=\"1067\" data-end=\"1091\"\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong data-start=\"1103\" data-end=\"1229\"\u003eToronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa\u003c\/strong\u003e, common symptoms of a failing ignition control include:\u003c\/p\u003e\n\u003cul data-start=\"1287\" data-end=\"1856\"\u003e\n\u003cli data-section-id=\"imqw2m\" data-start=\"1287\" data-end=\"1343\"\u003eFurnace does not ignite when there is a call for heat.\u003c\/li\u003e\n\u003cli data-section-id=\"1ck9xxd\" data-start=\"1344\" data-end=\"1392\"\u003eInducer motor starts but no spark is produced.\u003c\/li\u003e\n\u003cli data-section-id=\"1htvyzq\" data-start=\"1393\" data-end=\"1442\"\u003eSpark is present but the gas valve never opens.\u003c\/li\u003e\n\u003cli data-section-id=\"jkilet\" data-start=\"1443\" data-end=\"1504\"\u003eFurnace attempts ignition several times before locking out.\u003c\/li\u003e\n\u003cli data-section-id=\"rxi3qs\" data-start=\"1505\" data-end=\"1538\"\u003eIntermittent heating operation.\u003c\/li\u003e\n\u003cli data-section-id=\"130w6h6\" data-start=\"1539\" data-end=\"1609\"\u003eDiagnostic fault codes related to ignition failure or flame failure.\u003c\/li\u003e\n\u003cli data-section-id=\"bj4xm2\" data-start=\"1610\" data-end=\"1654\"\u003eBurners ignite briefly and then shut down.\u003c\/li\u003e\n\u003cli data-section-id=\"j0dz6l\" data-start=\"1655\" data-end=\"1721\"\u003eNo 24-volt output to the gas valve during the ignition sequence.\u003c\/li\u003e\n\u003cli data-section-id=\"1wze5hy\" data-start=\"1722\" data-end=\"1794\"\u003eFurnace enters safety lockout after repeated failed ignition attempts.\u003c\/li\u003e\n\u003cli data-section-id=\"14v58n9\" data-start=\"1795\" data-end=\"1856\"\u003eVisible signs of a burnt or damaged ignition control board.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53162252337428,"sku":null,"price":365.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem49W66.jpg?v=1785107454"},{"product_id":"lennox-16v38-heat-pump-defrost-control-board-100269-08","title":"Lennox 16V38 Heat Pump Defrost Control Board - 100269-08","description":"\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"86\" data-end=\"103\" class=\"PDq2pG_selectionAnchorContainer\"\u003eSpecifications\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"105\" data-end=\"778\"\u003e\n\u003cli data-section-id=\"1i64gt8\" data-start=\"105\" data-end=\"129\"\u003e\n\u003cstrong data-start=\"107\" data-end=\"123\"\u003ePart Number:\u003c\/strong\u003e 16V38\u003c\/li\u003e\n\u003cli data-section-id=\"rxzdzr\" data-start=\"130\" data-end=\"159\"\u003e\n\u003cstrong data-start=\"132\" data-end=\"149\"\u003eModel Number:\u003c\/strong\u003e 100269-08\u003c\/li\u003e\n\u003cli data-section-id=\"1wxntfb\" data-start=\"160\" data-end=\"179\"\u003e\n\u003cstrong data-start=\"162\" data-end=\"172\"\u003eBrand:\u003c\/strong\u003e Lennox\u003c\/li\u003e\n\u003cli data-section-id=\"f3so12\" data-start=\"180\" data-end=\"235\"\u003e\n\u003cstrong data-start=\"182\" data-end=\"199\"\u003eProduct Type:\u003c\/strong\u003e OEM Heat Pump Defrost Control Board\u003c\/li\u003e\n\u003cli data-section-id=\"ltgc90\" data-start=\"236\" data-end=\"289\"\u003e\n\u003cstrong data-start=\"238\" data-end=\"254\"\u003eApplication:\u003c\/strong\u003e Residential Heat Pump Outdoor Unit\u003c\/li\u003e\n\u003cli data-section-id=\"1dkj64l\" data-start=\"290\" data-end=\"319\"\u003e\n\u003cstrong data-start=\"292\" data-end=\"312\"\u003eControl Voltage:\u003c\/strong\u003e 24 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1k2j0h4\" data-start=\"320\" data-end=\"345\"\u003e\n\u003cstrong data-start=\"322\" data-end=\"336\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"mpnjfu\" data-start=\"346\" data-end=\"552\"\u003e\n\u003cstrong data-start=\"348\" data-end=\"362\"\u003eFunctions:\u003c\/strong\u003e\n\u003cul data-start=\"365\" data-end=\"552\"\u003e\n\u003cli data-section-id=\"1wr366c\" data-start=\"365\" data-end=\"399\"\u003eTime\/Temperature Defrost Control\u003c\/li\u003e\n\u003cli data-section-id=\"1x0xgba\" data-start=\"402\" data-end=\"417\"\u003eDefrost Relay\u003c\/li\u003e\n\u003cli data-section-id=\"72atx2\" data-start=\"420\" data-end=\"449\"\u003eAnti-Short Cycle Protection\u003c\/li\u003e\n\u003cli data-section-id=\"18xidj8\" data-start=\"452\" data-end=\"488\"\u003eHigh \u0026amp; Low Pressure Switch Control\u003c\/li\u003e\n\u003cli data-section-id=\"lwcyal\" data-start=\"491\" data-end=\"516\"\u003eManufacturing Test Mode\u003c\/li\u003e\n\u003cli data-section-id=\"y49j1w\" data-start=\"519\" data-end=\"552\"\u003eField Connection Terminal Strip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19aupau\" data-start=\"553\" data-end=\"646\"\u003e\n\u003cstrong data-start=\"555\" data-end=\"581\"\u003eCompressor Protection:\u003c\/strong\u003e 30-second compressor shutoff before and after the defrost cycle.\u003c\/li\u003e\n\u003cli data-section-id=\"1h6lgb4\" data-start=\"647\" data-end=\"669\"\u003e\n\u003cstrong data-start=\"649\" data-end=\"660\"\u003eWeight:\u003c\/strong\u003e 0.45 lbs\u003c\/li\u003e\n\u003cli data-section-id=\"8mchca\" data-start=\"670\" data-end=\"778\"\u003e\n\u003cstrong data-start=\"672\" data-end=\"685\"\u003eReplaces:\u003c\/strong\u003e 34M63, 84W88 and earlier 100269 series defrost boards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"780\" data-end=\"783\"\u003e\n\u003ch2 data-section-id=\"2tbkc4\" data-start=\"785\" data-end=\"861\"\u003eCommon Symptoms of a Failing Lennox 16V38 Heat Pump Defrost Control Board\u003c\/h2\u003e\n\u003cp data-start=\"863\" data-end=\"1474\"\u003eThe \u003cstrong data-start=\"867\" data-end=\"895\"\u003eLennox 16V38 (100269-08)\u003c\/strong\u003e is a \u003cstrong data-start=\"901\" data-end=\"936\"\u003eheat pump defrost control board\u003c\/strong\u003e, not a furnace control board. It controls the outdoor unit's defrost cycle, compressor protection, pressure switch monitoring, and overall heat pump operation during both heating and cooling. Whether you're located in \u003cstrong data-start=\"1155\" data-end=\"1212\"\u003eCalgary, Edmonton, Red Deer, Lethbridge, Medicine Hat\u003c\/strong\u003e, or elsewhere in \u003cstrong data-start=\"1230\" data-end=\"1241\"\u003eAlberta\u003c\/strong\u003e, or in the \u003cstrong data-start=\"1253\" data-end=\"1277\"\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong data-start=\"1289\" data-end=\"1415\"\u003eToronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa\u003c\/strong\u003e, a failing defrost board can cause the following problems:\u003c\/p\u003e\n\u003cul data-start=\"1476\" data-end=\"2179\"\u003e\n\u003cli data-section-id=\"irw1oc\" data-start=\"1476\" data-end=\"1552\"\u003eOutdoor heat pump becomes covered in ice and never enters a defrost cycle.\u003c\/li\u003e\n\u003cli data-section-id=\"1r47dat\" data-start=\"1553\" data-end=\"1606\"\u003eHeat pump stops producing heat during cold weather.\u003c\/li\u003e\n\u003cli data-section-id=\"15b90m9\" data-start=\"1607\" data-end=\"1654\"\u003eOutdoor unit starts and stops intermittently.\u003c\/li\u003e\n\u003cli data-section-id=\"pneald\" data-start=\"1655\" data-end=\"1734\"\u003eCompressor will not start even though there is a call for heating or cooling.\u003c\/li\u003e\n\u003cli data-section-id=\"m3aanf\" data-start=\"1735\" data-end=\"1798\"\u003eHeat pump locks out on high- or low-pressure safety switches.\u003c\/li\u003e\n\u003cli data-section-id=\"totjb5\" data-start=\"1799\" data-end=\"1897\"\u003eAuxiliary or emergency heat runs more often because the outdoor unit is not operating correctly.\u003c\/li\u003e\n\u003cli data-section-id=\"1vf82ni\" data-start=\"1898\" data-end=\"1960\"\u003eUnit short cycles due to a failed anti-short-cycle function.\u003c\/li\u003e\n\u003cli data-section-id=\"1i5qd0g\" data-start=\"1961\" data-end=\"2023\"\u003eDefrost cycle runs too often or does not terminate properly.\u003c\/li\u003e\n\u003cli data-section-id=\"1famunn\" data-start=\"2024\" data-end=\"2084\"\u003eDiagnostic LEDs display fault codes or fail to illuminate.\u003c\/li\u003e\n\u003cli data-section-id=\"1rjub1f\" data-start=\"2085\" data-end=\"2179\"\u003eIntermittent heating and cooling caused by an internal failure of the defrost control board.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53162260824340,"sku":null,"price":300.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem16V38.jpg?v=1785107781"},{"product_id":"lennox-59w47-control-board-102630-01-m2-unit-replacement-kit","title":"Lennox 59W47 Control Board 102630-01 M2 Unit Replacement Kit","description":"\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"79\" data-end=\"96\" class=\"PDq2pG_selectionAnchorContainer\"\u003eSpecifications\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"98\" data-end=\"613\"\u003e\n\u003cli data-section-id=\"1i3nof2\" data-start=\"98\" data-end=\"122\"\u003e\n\u003cstrong data-start=\"100\" data-end=\"116\"\u003ePart Number:\u003c\/strong\u003e 59W47\u003c\/li\u003e\n\u003cli data-section-id=\"1k7fjp0\" data-start=\"123\" data-end=\"152\"\u003e\n\u003cstrong data-start=\"125\" data-end=\"142\"\u003eModel Number:\u003c\/strong\u003e 102630-01\u003c\/li\u003e\n\u003cli data-section-id=\"1wxntfb\" data-start=\"153\" data-end=\"172\"\u003e\n\u003cstrong data-start=\"155\" data-end=\"165\"\u003eBrand:\u003c\/strong\u003e Lennox\u003c\/li\u003e\n\u003cli data-section-id=\"z9aqtn\" data-start=\"173\" data-end=\"231\"\u003e\n\u003cstrong data-start=\"175\" data-end=\"192\"\u003eProduct Type:\u003c\/strong\u003e OEM M2 Unit Controller Replacement Kit\u003c\/li\u003e\n\u003cli data-section-id=\"1wi6y01\" data-start=\"232\" data-end=\"274\"\u003e\n\u003cstrong data-start=\"234\" data-end=\"252\"\u003eAlso Known As:\u003c\/strong\u003e Prodigy Control Board\u003c\/li\u003e\n\u003cli data-section-id=\"1cb8wbl\" data-start=\"275\" data-end=\"334\"\u003e\n\u003cstrong data-start=\"277\" data-end=\"293\"\u003eApplication:\u003c\/strong\u003e Commercial Packaged Rooftop Units (RTUs)\u003c\/li\u003e\n\u003cli data-section-id=\"1dkj64l\" data-start=\"335\" data-end=\"364\"\u003e\n\u003cstrong data-start=\"337\" data-end=\"357\"\u003eControl Voltage:\u003c\/strong\u003e 24 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"3txwo5\" data-start=\"365\" data-end=\"458\"\u003e\n\u003cstrong data-start=\"367\" data-end=\"380\"\u003eIncludes:\u003c\/strong\u003e M2 Unit Controller Board, installation hardware, and setup\/installation guide\u003c\/li\u003e\n\u003cli data-section-id=\"1903uil\" data-start=\"459\" data-end=\"486\"\u003e\n\u003cstrong data-start=\"461\" data-end=\"478\"\u003eGross Weight:\u003c\/strong\u003e 2.4 lbs\u003c\/li\u003e\n\u003cli data-section-id=\"1pnvg4s\" data-start=\"487\" data-end=\"613\"\u003e\n\u003cstrong data-start=\"489\" data-end=\"505\"\u003eReplacement:\u003c\/strong\u003e Superseded by newer Lennox replacement kits for certain applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"615\" data-end=\"618\"\u003e\n\u003ch2 data-section-id=\"1mlblzn\" data-start=\"620\" data-end=\"683\"\u003eCommon Symptoms of a Failing Lennox 59W47 M2 Unit Controller\u003c\/h2\u003e\n\u003cp data-start=\"685\" data-end=\"1343\"\u003eThe \u003cstrong data-start=\"689\" data-end=\"717\"\u003eLennox 59W47 (102630-01)\u003c\/strong\u003e M2 Unit Controller, commonly referred to as the \u003cstrong data-start=\"766\" data-end=\"791\"\u003eProdigy Control Board\u003c\/strong\u003e, is the primary control board used in many \u003cstrong data-start=\"835\" data-end=\"882\"\u003eLennox commercial rooftop HVAC units (RTUs)\u003c\/strong\u003e. It manages heating, cooling, blower operation, safety circuits, and system communication. Whether your rooftop unit is servicing a building in \u003cstrong data-start=\"1027\" data-end=\"1084\"\u003eCalgary, Edmonton, Red Deer, Lethbridge, Medicine Hat\u003c\/strong\u003e, or elsewhere in \u003cstrong data-start=\"1102\" data-end=\"1113\"\u003eAlberta\u003c\/strong\u003e, or in the \u003cstrong data-start=\"1125\" data-end=\"1149\"\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong data-start=\"1161\" data-end=\"1287\"\u003eToronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa\u003c\/strong\u003e, a failing controller may cause the following symptoms:\u003c\/p\u003e\n\u003cul data-start=\"1345\" data-end=\"1877\"\u003e\n\u003cli data-section-id=\"1a8o9jo\" data-start=\"1345\" data-end=\"1375\"\u003eRooftop unit will not start.\u003c\/li\u003e\n\u003cli data-section-id=\"19gq4ke\" data-start=\"1376\" data-end=\"1456\"\u003eNo heating or cooling despite a thermostat or building automation system call.\u003c\/li\u003e\n\u003cli data-section-id=\"bh7kin\" data-start=\"1457\" data-end=\"1494\"\u003eIndoor supply fan fails to operate.\u003c\/li\u003e\n\u003cli data-section-id=\"20q9dm\" data-start=\"1495\" data-end=\"1526\"\u003eCompressors fail to energize.\u003c\/li\u003e\n\u003cli data-section-id=\"1c4ong8\" data-start=\"1527\" data-end=\"1558\"\u003eHeating stages do not engage.\u003c\/li\u003e\n\u003cli data-section-id=\"h07i0k\" data-start=\"1559\" data-end=\"1611\"\u003eIntermittent system operation or random shutdowns.\u003c\/li\u003e\n\u003cli data-section-id=\"i86fgi\" data-start=\"1612\" data-end=\"1687\"\u003eUnit locks out on safety faults even after components have been verified.\u003c\/li\u003e\n\u003cli data-section-id=\"6x1ta7\" data-start=\"1688\" data-end=\"1738\"\u003eLoss of communication between system components.\u003c\/li\u003e\n\u003cli data-section-id=\"1famunn\" data-start=\"1739\" data-end=\"1799\"\u003eDiagnostic LEDs display fault codes or fail to illuminate.\u003c\/li\u003e\n\u003cli data-section-id=\"gn0pex\" data-start=\"1800\" data-end=\"1877\"\u003eBurnt relays or visible damage on the control board from electrical surges.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53162272227604,"sku":null,"price":1508.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem59W47.jpg?v=1785108308"},{"product_id":"lennox-63w27-ignition-control-board-100870-3","title":"Lennox 63W27 Ignition Control Board (100870-03)","description":"\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 63W27\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 100870-03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Lennox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Ignition Control Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e 2-Stage Variable Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 18–30 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Model:\u003c\/strong\u003e Honeywell S9230F1014\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Select Lennox two-stage variable speed gas furnaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Models Include:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eG60DFV\u003c\/li\u003e\n\u003cli\u003eG60UHV\u003c\/li\u003e\n\u003cli\u003eG61MPV\u003c\/li\u003e\n\u003cli\u003eSL280DFV\u003c\/li\u003e\n\u003cli\u003eSL280UHV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGenuine OEM Lennox Replacement Part\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Symptoms\u003c\/h3\u003e\n\u003cp\u003eIf your Lennox furnace in \u003cstrong\u003eCalgary, Edmonton, Red Deer, Lethbridge, Medicine Hat\u003c\/strong\u003e, or elsewhere in \u003cstrong\u003eAlberta\u003c\/strong\u003e, or throughout the \u003cstrong\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong\u003eToronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering,\u003c\/strong\u003e and \u003cstrong\u003eOshawa\u003c\/strong\u003e, won't ignite, keeps locking out, or the igniter or gas valve isn't being energized, the \u003cstrong\u003eLennox 63W27 Ignition Control Board (100870-03)\u003c\/strong\u003e may need to be replaced.\u003c\/p\u003e\n\u003cp\u003ePurchase the \u003cstrong\u003eLennox 63W27 Ignition Control Board (100870-03)\u003c\/strong\u003e from \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53467471479060,"sku":null,"price":475.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem63W27_2ae3b4f9-7408-4b35-8833-9b6deb54dc1c.jpg?v=1785526506"},{"product_id":"lennox-94w83-ignition-control-board-103085-03","title":"Lennox 94W83 Ignition Control Board (103085-03)","description":"\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 94W83\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 103085-03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Lennox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Ignition Control Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Single-Stage PSC Motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 18–30 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Model:\u003c\/strong\u003e UTEC 1012-977A-I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Select Lennox single-stage gas furnaces with PSC blower motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e 81W11 and 103085-03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Lennox Replacement Part\u003c\/strong\u003e \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Symptoms\u003c\/h3\u003e\n\u003cp\u003eIf your Lennox furnace in \u003cstrong\u003eCalgary, Edmonton, Red Deer, Lethbridge, Medicine Hat\u003c\/strong\u003e, or elsewhere in \u003cstrong\u003eAlberta\u003c\/strong\u003e, or throughout the \u003cstrong\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong\u003eToronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering,\u003c\/strong\u003e and \u003cstrong\u003eOshawa\u003c\/strong\u003e, won't ignite, the blower runs continuously, or the furnace repeatedly locks out, the \u003cstrong\u003eLennox 94W83 Ignition Control Board (103085-03)\u003c\/strong\u003e may need to be replaced. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePurchase the \u003cstrong\u003eLennox 94W83 Ignition Control Board (103085-03)\u003c\/strong\u003e from \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53468288418068,"sku":null,"price":300.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem94w83.jpg?v=1785527022"},{"product_id":"carrier-ceso110074-01-ignition-control-board","title":"Carrier CESO110074-01 Ignition Control Board","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e CESO110074-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Carrier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Ignition Control Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Select Carrier, Bryant, and Payne gas furnaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e CESO110074-00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeatures:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated diagnostic LED\u003c\/li\u003e\n\u003cli\u003e100% safety lockout\u003c\/li\u003e\n\u003cli\u003eControls inducer motor, blower operation, ignition sequence, and gas valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Carrier Replacement Part\u003c\/strong\u003e \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Symptoms\u003c\/h3\u003e\n\u003cp\u003eIf your Carrier, Bryant, or Payne furnace in \u003cstrong\u003eCalgary, Edmonton, Red Deer, Lethbridge, Medicine Hat\u003c\/strong\u003e, or elsewhere in \u003cstrong\u003eAlberta\u003c\/strong\u003e, or throughout the \u003cstrong\u003eGreater Toronto Area\u003c\/strong\u003e, including \u003cstrong\u003eToronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering,\u003c\/strong\u003e and \u003cstrong\u003eOshawa\u003c\/strong\u003e, won't ignite, the blower runs continuously, or the furnace repeatedly locks out, the \u003cstrong\u003eCarrier CESO110074-01 Ignition Control Board\u003c\/strong\u003e may need to be replaced. \u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePurchase the \u003cstrong\u003eCarrier CESO110074-01 Ignition Control Board\u003c\/strong\u003e from \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53470508581140,"sku":null,"price":730.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oemCESO110074-01.jpg?v=1785528271"},{"product_id":"lennox-19m54-ignition-control-board-065310400","title":"Lennox 19M54 Ignition Control Board (065310400)","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 19M54\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 065310400\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ignition Control Board Conversion Kit\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox LF\/LD Series Unit Heaters and Compatible Heating Equipment\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eVoltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 18\/30 VAC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eReplacement Control Board:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e UTEC 23L53 (065312200) GCI-3A Ignition\/Blower Control Board\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eKit Includes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUTEC 23L53 Ignition\/Blower Control Board\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e9-to-6 Pin Wiring Harness Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e15-to-6 Pin Wiring Harness Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWiring Diagram Label\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBurner Box Tops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eControl Board Mounting Plate\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBrown Jumper Wire\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGreen\/Yellow Ground Wire Assembly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBlack Lead Wire\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIgniter Wire\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eUnit Conversion Sticker\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGenuine OEM Replacement Part\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your Lennox unit heater or compatible heating equipment in Calgary, Edmonton, Red Deer, Lethbridge, Medicine Hat, or anywhere in Alberta, or throughout the Greater Toronto Area, including Toronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa, is experiencing ignition failures, intermittent heating, repeated ignition lockouts, no spark, no burner operation, blower control issues, or a failed ignition control board, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox 19M54 Ignition Control Board Conversion Kit (065310400)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may be the correct replacement. This genuine OEM conversion kit upgrades older GCI-3, RAM-3MC5, and EGC-2 control boards to the newer GCI-3A control platform, restoring safe and reliable furnace or unit heater operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBuy your genuine OEM \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox 19M54 Ignition Control Board Conversion Kit (065310400)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from \u003c\/span\u003e\u003ca href=\"https:\/\/oemhvacpartscanada.ca\/pages\/home\" title=\"https:\/\/oemhvacpartscanada.ca\/pages\/home\"\u003e\u003cstrong\u003e\u003cspan\u003eOemHvacPartsCanada.ca\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53560933974292,"sku":null,"price":875.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem19M54.jpg?v=1785610051"},{"product_id":"lennox-y9894-integrated-furnace-control-board-50a66-743","title":"Lennox Y9894 Integrated Furnace Control Board (50A66-743)","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Y9894\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50A66-743\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOEM Board Manufacturer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e White-Rodgers\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Integrated Furnace Control Board\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox Single-Stage Gas Furnaces\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eIgnition Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Hot Surface Ignition (HSI)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eIgnitor Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 80 VAC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eHeating Stages:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Single Stage\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Blower Motor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e PSC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Inducer Motor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e PSC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eThermostat Inputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e R, C, W, Y, G\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eMounting:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Standoff\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGenuine OEM Replacement Part\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your Lennox furnace in Calgary, Edmonton, Red Deer, Lethbridge, Medicine Hat, or anywhere in Alberta, or throughout the Greater Toronto Area, including Toronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa, is experiencing intermittent heating, ignition failures, repeated ignition lockouts, the inducer motor running without burner ignition, the blower failing to operate properly, or the furnace not completing the heating cycle, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox Y9894 Integrated Furnace Control Board (50A66-743)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may need to be replaced. This genuine OEM control board is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox single-stage furnaces with an 80 VAC hot surface ignitor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, restoring proper ignition sequencing, blower operation, and overall furnace reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBuy your genuine OEM \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox Y9894 Integrated Furnace Control Board (50A66-743)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from\u003ca href=\"https:\/\/oemhvacpartscanada.ca\/pages\/home\" title=\"https:\/\/oemhvacpartscanada.ca\/pages\/home\"\u003e \u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/oemhvacpartscanada.ca\/pages\/home\" title=\"https:\/\/oemhvacpartscanada.ca\/pages\/home\"\u003e\u003cstrong\u003e\u003cspan\u003eOemHvacPartsCanada.ca\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53561948209428,"sku":null,"price":450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oemY9894.jpg?v=1785617425"},{"product_id":"lennox-19v36-surelight-ignition-control-board-kit-lb-109531b","title":"Lennox 19V36 SureLight Ignition Control Board Kit (LB-109531B)","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 19V36\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e LB-109531B\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e SureLight Ignition Control Board Kit\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox Single-Stage Gas Furnaces\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eIgnition Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Hot Surface Ignition (HSI)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eKit Includes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSureLight Ignition Control Board\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement Hot Surface Ignitor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIgnitor Mounting Brackets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e9-Pin to 12-Pin Wiring Harness Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4-Pin to 6-Pin Wiring Harness Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIgnitor Harness Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDiagnostic Sticker\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWiring Diagram\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMounting Hardware\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGenuine OEM Replacement Part\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your Lennox furnace in Calgary, Edmonton, Red Deer, Lethbridge, Medicine Hat, or anywhere in Alberta, or throughout the Greater Toronto Area, including Toronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa, is experiencing intermittent heating, ignition failures, repeated ignition lockouts, the inducer motor running without burner ignition, a hot surface ignitor that doesn't energize, no blower operation after a call for heat, or diagnostic fault codes indicating a failed control board, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox 19V36 SureLight Ignition Control Board Kit (LB-109531B)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may need to be replaced. This genuine OEM kit includes the updated SureLight control board, replacement hot surface ignitor, wiring harness adapters, and installation hardware to restore proper ignition sequencing and reliable furnace operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBuy your genuine OEM \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox 19V36 SureLight Ignition Control Board Kit (LB-109531B)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from\u003ca href=\"https:\/\/oemhvacpartscanada.ca\/pages\/about-us\" title=\"https:\/\/oemhvacpartscanada.ca\/pages\/about-us\"\u003e \u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/oemhvacpartscanada.ca\/pages\/about-us\" title=\"https:\/\/oemhvacpartscanada.ca\/pages\/about-us\"\u003e\u003cstrong\u003e\u003cspan\u003eOemHvacPartsCanada.ca\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53567330943252,"sku":null,"price":600.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem19v36controlboard.jpg?v=1785711095"},{"product_id":"rheem-62-103189-01-integrated-furnace-control-board","title":"Rheem 62-103189-01 Integrated Furnace Control Board","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 62-103189-01\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Rheem\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Integrated Furnace Control Board\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Rheem and Ruud Gas Furnaces\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eControl Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Integrated Furnace Control (IFC)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eIgnition Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Hot Surface Ignition (HSI)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eHeating Stages:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Single Stage\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eControl Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 24 VAC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eLine Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 120 VAC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOEM Replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGenuine OEM Replacement Part\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your Rheem or Ruud furnace in Calgary, Edmonton, Red Deer, Lethbridge, Medicine Hat, or anywhere in Alberta, or throughout the Greater Toronto Area, including Toronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa, is experiencing intermittent heating, ignition failures, repeated ignition lockouts, the inducer motor running without burner ignition, the blower not operating correctly, no call for heat, or diagnostic fault codes indicating a failed control board, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRheem 62-103189-01 Integrated Furnace Control Board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may need to be replaced. This genuine OEM integrated furnace control board manages the ignition sequence, blower timing, and safety functions to restore reliable furnace operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBuy your genuine OEM \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRheem 62-103189-01 Integrated Furnace Control Board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from \u003c\/span\u003e\u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003e\u003cstrong\u003e\u003cspan\u003eOemHvacPartsCanada.ca\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53587039289620,"sku":null,"price":450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem62-103189-01.jpg?v=1785763167"},{"product_id":"lennox-17w82-ignition-control-replacement-kit-lb-91097c","title":"Lennox 17W82 Ignition Control Replacement Kit (LB-91097C)","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 17W82\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e LB-91097C\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ignition Control Replacement Kit\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox Gas Furnaces\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eControl Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EGC-1 Ignition Control Conversion Kit\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eKit Includes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eIgnition Control Board (100980-01)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIgnition Wire (73K76)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallation Instructions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eAdditional conversion components for applicable models\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eReplaces:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EGC-1 and EGC-2 ignition controls in compatible Lennox furnaces\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGenuine OEM Replacement Part\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your Lennox furnace in Calgary, Edmonton, Red Deer, Lethbridge, Medicine Hat, or anywhere in Alberta, or throughout the Greater Toronto Area, including Toronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa, is experiencing intermittent heating, no spark ignition, ignition lockouts, the inducer motor running without burner ignition, failure to complete the ignition sequence, or a failed EGC-1 or EGC-2 ignition control, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox 17W82 Ignition Control Replacement Kit (LB-91097C)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may need to be replaced. This genuine OEM conversion kit replaces older \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEGC-1 and EGC-2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ignition controls with an updated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEGC-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e control and includes the necessary ignition wire and installation components to restore safe and reliable furnace operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBuy your genuine OEM \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox 17W82 Ignition Control Replacement Kit (LB-91097C)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from \u003c\/span\u003e\u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003e\u003cstrong\u003e\u003cspan\u003eOemHvacPartsCanada.ca\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53587088474388,"sku":null,"price":535.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem17w82.jpg?v=1785768002"},{"product_id":"lennox-19s83-blower-control-board-kit-621344-01","title":"Lennox 19S83 Blower Control Board Kit (621344-01)","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 19S83\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer Part Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 621344-01\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Blower Control Board Kit (BCC3 Replacement)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lennox Gas Furnaces\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCompatible Series:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e G20, G20R, G23, G26, O23, OF23, and OHR23 Series Units\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eKit Includes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBlower Control Board (106363-01)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWire Harness (106364-01)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eInstallation Instructions\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGenuine OEM Replacement Part\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your Lennox furnace in Calgary, Edmonton, Red Deer, Lethbridge, Medicine Hat, or anywhere in Alberta, or throughout the Greater Toronto Area, including Toronto, Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington, Milton, Ajax, Pickering, and Oshawa, is experiencing a blower motor that won't start, intermittent blower operation, no airflow, the blower running continuously, delayed blower operation, or diagnostic fault codes indicating a failed blower control board, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox 19S83 Blower Control Board Kit (621344-01)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may need to be replaced. This genuine OEM BCC3 replacement kit includes the updated blower control board and wiring harness to restore proper blower operation and dependable furnace performance in compatible Lennox heating systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBuy your genuine OEM \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLennox 19S83 Blower Control Board Kit (621344-01)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from \u003c\/span\u003e\u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003e\u003cstrong\u003e\u003cspan\u003eOemHvacPartsCanada.ca\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53588075249940,"sku":null,"price":475.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem19S83.jpg?v=1785792042"},{"product_id":"honeywell-s8610u3009-universal-pilot-ignition-module","title":"Honeywell S8610U3009 Universal Pilot Ignition Module","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e S8610U3009\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eManufacturer Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e S8610U3009\/U\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Resideo \/ Honeywell Home\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Universal Intermittent Pilot Ignition Module\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eVoltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 24 VAC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 60 Hz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eIgnition Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Intermittent Pilot Ignition\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eIgnition Source:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Internal High-Voltage Spark Generator\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eIgnition Trial Time:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Configurable 15 or 90 Seconds\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePre-Purge:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Configurable 0 or 30 Seconds\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFlame Sensing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Single Rod or Two-Rod \/ Remote Sense\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGas Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Natural Gas or LP\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFlame Failure Response:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 2 Seconds\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -40°F to 165°F (-40°C to 74°C)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Furnaces, Boilers and Other Compatible Gas-Fired Heating Equipment\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSafety Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ignition Sequencing, Flame Monitoring and Safety Shutoff\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eReplacement Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Universal Service Replacement Ignition Control\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eResideo Honeywell S8610U3009\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a universal intermittent pilot ignition control designed for servicing gas-fired furnaces, boilers and other heating equipment that use an intermittent pilot ignition system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe module controls the ignition sequence, generates the spark for pilot ignition, monitors the pilot flame and controls the gas valve during the heating cycle.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe S8610U3009 is designed as a universal replacement and can replace more than 400 intermittent pilot ignition modules from manufacturers including Honeywell\/Resideo, White-Rodgers, Robertshaw, Johnson Controls and UTEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Symptoms of a Failed S8610U3009 Ignition Module\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA faulty intermittent pilot ignition module can cause:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eNo spark during a call for heat\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePilot will not ignite\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePilot lights but main burners do not ignite\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMain gas valve does not energize\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFurnace or boiler repeatedly attempts ignition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePilot lights and then shuts down\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBurners operate intermittently\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIgnition sequence stops before the main burner starts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eModule does not respond to a call for heat\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSystem repeatedly enters ignition retry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame is present but the module does not recognize the flame\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating equipment works intermittently and then fails to ignite\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese symptoms can also be caused by problems with the pilot assembly, flame-sensing circuit, gas valve, wiring, grounding or other components in the heating system. Proper diagnosis should be performed before replacing the ignition module.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eUniversal Replacement Ignition Control\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eS8610U3009\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is specifically designed to simplify replacement of older intermittent pilot ignition controls. It can be used in both single-rod and separate flame-sensor applications and includes spark cable adapters for replacing various OEM and competitive ignition controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause this is a universal replacement control, the original ignition module number and equipment requirements should be checked against the manufacturer's cross-reference information before replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eS8610U3009 Furnace and Boiler Ignition Module\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eResideo Honeywell S8610U3009 Universal Intermittent Pilot Ignition Module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is used on compatible gas furnaces, boilers and other gas-fired heating appliances equipped with intermittent pilot ignition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways verify the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eS8610U3009 part number, voltage, ignition configuration and equipment compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBuy the Resideo Honeywell S8610U3009 Universal Intermittent Pilot Ignition Module from \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003eOemHvacPartsCanada.ca.\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53615044952340,"sku":null,"price":385.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oemS8610U3009.jpg?v=1786200085"},{"product_id":"rheem-62-24140-04-furnace-control-board","title":"Rheem 62-24140-04 Furnace Control Board","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 62-24140-04\u003cbr\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Rheem \/ Ruud\u003cbr\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Furnace Control Board\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas Furnaces\u003cbr\u003e\u003cstrong\u003eIgnition Type:\u003c\/strong\u003e Direct Spark Ignition (DSI)\u003cbr\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 115 VAC\u003cbr\u003e\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24 VAC\u003cbr\u003e\u003cstrong\u003eInducer Control:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eGas Valve Control:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eIgnition Control:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eFlame Sensing:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eIndoor Blower Control:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eCooling Control:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eDiagnostic LED:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eOEM Replacement Part:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003ch2\u003eCommon Symptoms of a Failed 62-24140-04 Control Board\u003c\/h2\u003e\n\u003cp\u003eA failed or failing \u003cstrong\u003eRheem 62-24140-04 control board\u003c\/strong\u003e may cause the furnace to not respond to a call for heat, the inducer motor to not start, no spark at the ignitor, the gas valve to not energize, burners to fail to ignite, the indoor blower to not operate, the blower to run continuously, intermittent heating operation, repeated ignition lockouts, or the furnace to stop during the heating sequence.\u003c\/p\u003e\n\u003cp\u003eA control board failure can also affect \u003cstrong\u003eAC operation\u003c\/strong\u003e if the board is not properly responding to the thermostat's cooling call or is failing to energize the indoor blower during cooling.\u003c\/p\u003e\n\u003ch2\u003eReplacement Information\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e62-24140-04\u003c\/strong\u003e is used on select Rheem and Ruud furnace systems. Always confirm the furnace model number and existing control board part number before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuy the Rheem 62-24140-04 Furnace Control Board from \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003eOemHvacPartsCanada.ca.\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53615055438100,"sku":null,"price":350.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem62-24140-04-1.jpg?v=1786201462"},{"product_id":"honeywell-s9200u1000-universal-furnace-control-board","title":"Honeywell S9200U1000 Universal Furnace Control Board","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e S9200U1000\u003cbr\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo \/ Honeywell Home\u003cbr\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Universal Furnace Control Board\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Single-Stage Gas Furnaces\u003cbr\u003e\u003cstrong\u003eIgnition Type:\u003c\/strong\u003e Hot Surface Ignition (HSI)\u003cbr\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 VAC \/ 24 VAC Control\u003cbr\u003e\u003cstrong\u003eFlame Sensing:\u003c\/strong\u003e Flame Rectification\u003cbr\u003e\u003cstrong\u003eIgnition Trials:\u003c\/strong\u003e 3\u003cbr\u003e\u003cstrong\u003eDiagnostic LEDs:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eInducer Control:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eBlower Control:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eGas Valve Control:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eTwinning Capability:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eUniversal Replacement:\u003c\/strong\u003e Replaces 195+ furnace controls\u003c\/p\u003e\n\u003ch2\u003eCommon Symptoms of a Failed S9200U1000\u003c\/h2\u003e\n\u003cp\u003eA failed \u003cstrong\u003eS9200U1000 control board\u003c\/strong\u003e may cause no heat, inducer not starting, no power to the hot surface igniter, gas valve not opening, burners not firing, blower not operating, blower running continuously, intermittent operation, ignition lockouts, or no response from the furnace during a call for heat.\u003c\/p\u003e\n\u003cp\u003eA failed board can also cause \u003cstrong\u003eAC blower problems\u003c\/strong\u003e during a cooling call.\u003c\/p\u003e\n\u003ch2\u003eReplacement\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eS9200U1000\u003c\/strong\u003e is a universal replacement for many single-stage HSI furnace control boards. Always confirm the original board number and furnace application before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuy the Resideo Honeywell S9200U1000 Furnace Control Board from OemHvacPartsCanada.ca.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53615572418836,"sku":null,"price":360.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oemS9200U1000.jpg?v=1786223234"},{"product_id":"carrier-hh84aa020-furnace-blower-control-board","title":"Carrier HH84AA020 Furnace Blower Control Board","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e HH84AA020\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Carrier \/ Bryant \/ Payne\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Furnace Blower Control Board\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Gas Furnaces\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eControl Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 18–30 VAC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003ePower Consumption:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 5 Watts Maximum\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eN.O. Contact Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 20 Amps Resistive @ 240 VAC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eN.C. Contact Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10 Amps Resistive @ 240 VAC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBlower Run Time Delay:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fixed\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Controls furnace blower operation\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOEM Replacement Part:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eReplaces\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eHH84AA011\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eHH84AA010\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eHH84AA013\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eCESO110018\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e302075-301\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e302075-302\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e302075-304\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e302075-352\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e302075-354\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e58GS302075352\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e58GS302075354\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCarrier HH84AA020\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is used on select Carrier, Bryant and Payne furnaces and controls blower operation during heating and cooling cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Symptoms of a Failed HH84AA020 Control Board\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA failed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHH84AA020 blower control board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may cause the blower motor to not start, blower to run continuously, intermittent blower operation, no blower during a call for heat, no blower during AC operation, incorrect blower operation, or the furnace to stop responding properly to thermostat calls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways confirm the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHH84AA020 part number and furnace model number\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBuy the Carrier HH84AA020 Furnace Blower Control Board from OemHvacPartsCanada.ca.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53621762752788,"sku":null,"price":300.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oemHH84AA020.jpg?v=1786399949"},{"product_id":"icp-1172809-two-stage-furnace-control-board","title":"ICP 1172809 Two-Stage Furnace Control Board","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1172809\u003cbr\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e ICP – International Comfort Products\u003cbr\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Furnace Control Board\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas Furnace\u003cbr\u003e\u003cstrong\u003eStages:\u003c\/strong\u003e 2-Stage\u003cbr\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003cbr\u003e\u003cstrong\u003eReplaces:\u003c\/strong\u003e 1172551\u003cbr\u003e\u003cstrong\u003eOther Board Numbers:\u003c\/strong\u003e HK42FZ020, CEPL130591-01, CEPL130591-41 \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eICP 1172809 Furnace Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eICP 1172809\u003c\/strong\u003e is a two-stage furnace control board used in select ICP gas furnaces. The board controls and monitors furnace operation including the inducer motor, ignition sequence, gas valve, blower operation, and furnace safety circuits. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1172809 is used across several International Comfort Products brands including \u003cstrong\u003eKeeprite, Heil, Tempstar, Comfortmaker, and Arcoaire\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Furnace Models\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e1172809 control board\u003c\/strong\u003e is used in furnace models including:\u003c\/p\u003e\n\u003cp\u003eC8MPV050B12B1, C8MPV050B12C1, C8MPV075F14B1, C8MPV075F14C1, C8MPV100J20B1, C8MPV100J20C1, C8MPV125J20B1, C8MPV125J20C1, H8MPV050B12B1, H8MPV050B12C1, H8MPV075F14B1, H8MPV075F14C1, H8MPV100J20B1, H8MPV100J20C1, H8MPV125J20B1 and H8MPV125J20C1. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Symptoms of a Failed 1172809 Control Board\u003c\/h2\u003e\n\u003cp\u003eA failed \u003cstrong\u003e1172809 furnace control board\u003c\/strong\u003e can cause the furnace to not start, inducer motor to not receive power, ignition sequence problems, gas valve not opening, blower motor not operating correctly, intermittent furnace operation, incorrect two-stage operation, or a completely unresponsive furnace.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuy the ICP 1172809 Two-Stage Furnace Control Board from \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003eOemHvacPartsCanada.ca.\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53622826533140,"sku":null,"price":740.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem1172809.jpg?v=1786411421"},{"product_id":"1184412-furnace-control-board","title":"1184412 Furnace Control Board","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1184412\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e International Comfort Products (ICP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Ignition \/ Furnace Control Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse:\u003c\/strong\u003e 3 Amp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 5 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas Furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFurnace Series:\u003c\/strong\u003e G9MXE \/ F9MXE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStages:\u003c\/strong\u003e Two Stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Replacement Control Board\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cp\u003eUsed on select furnaces from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eICP\u003c\/li\u003e\n\u003cli\u003eHeil\u003c\/li\u003e\n\u003cli\u003eTempstar\u003c\/li\u003e\n\u003cli\u003eKeepRite\u003c\/li\u003e\n\u003cli\u003eComfortmaker\u003c\/li\u003e\n\u003cli\u003eArcoaire\u003c\/li\u003e\n\u003cli\u003eDay \u0026amp; Night \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e1184412\u003c\/strong\u003e is used on G9MXE and F9MXE furnace models including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eG9MXE0261410A2\u003c\/li\u003e\n\u003cli\u003eG9MXE0401410A1 \/ A2\u003c\/li\u003e\n\u003cli\u003eG9MXE0401712A1\u003c\/li\u003e\n\u003cli\u003eG9MXE0601412A1\u003c\/li\u003e\n\u003cli\u003eG9MXE0601714A1 \/ A2\u003c\/li\u003e\n\u003cli\u003eG9MXE0801716A1 \/ A2\u003c\/li\u003e\n\u003cli\u003eG9MXE0802120A1 \/ A2\u003c\/li\u003e\n\u003cli\u003eG9MXE1002116A1\u003c\/li\u003e\n\u003cli\u003eG9MXE1002120A1 \/ A2\u003c\/li\u003e\n\u003cli\u003eG9MXE1202422A1 \/ A2\u003c\/li\u003e\n\u003cli\u003eF9MXE series equivalents \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInternational Comfort Products 1184412 Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e1184412\u003c\/strong\u003e is the main furnace control board. It controls the furnace heating sequence, including ignition, inducer operation and blower operation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Signs of a Failed 1184412 Control Board\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not start\u003c\/li\u003e\n\u003cli\u003eInducer motor will not energize\u003c\/li\u003e\n\u003cli\u003eIgnitor will not energize\u003c\/li\u003e\n\u003cli\u003eGas valve not receiving 24V\u003c\/li\u003e\n\u003cli\u003eBlower motor not operating correctly\u003c\/li\u003e\n\u003cli\u003eFurnace starts but shuts down during the heating cycle\u003c\/li\u003e\n\u003cli\u003eIntermittent furnace operation\u003c\/li\u003e\n\u003cli\u003eIncorrect or inconsistent furnace sequence\u003c\/li\u003e\n\u003cli\u003eNo response to a call for heat\u003c\/li\u003e\n\u003cli\u003eBurnt or damaged components on the board\u003c\/li\u003e\n\u003cli\u003eBlown 3A fuse\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuy ICP 1184412 Furnace Control Board in Canada\u003c\/h2\u003e\n\u003cp\u003eBuy the \u003cstrong\u003eInternational Comfort Products 1184412 Furnace Control Board\u003c\/strong\u003e from \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e for ICP, Heil, Tempstar, KeepRite and Comfortmaker furnace parts across Canada.\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53625718538516,"sku":null,"price":655.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem1184412.jpg?v=1786481979"},{"product_id":"icp-1172550-24v-single-stage-furnace-control-board","title":"ICP 1172550 24V Single-Stage Furnace Control Board","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1172550\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e International Comfort Products (ICP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Integrated Furnace Control Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStages:\u003c\/strong\u003e Single Stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas Furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard Width:\u003c\/strong\u003e 5 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Replacement Part:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWolseley identifies the 1172550 specifically as a \u003cstrong\u003e24V, 5-inch, single-stage ignition and furnace control board\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eICP 1172550 Furnace Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eInternational Comfort Products 1172550\u003c\/strong\u003e is an integrated furnace control board used in select ICP gas furnaces.\u003c\/p\u003e\n\u003cp\u003eThe board controls furnace operation including the ignition sequence and other furnace functions. It is used across a large number of ICP-manufactured furnace models. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompatible Furnace Brands\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eICP 1172550\u003c\/strong\u003e is used in select furnaces sold under International Comfort Products brands, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKeepRite\u003c\/li\u003e\n\u003cli\u003eHeil\u003c\/li\u003e\n\u003cli\u003eTempstar\u003c\/li\u003e\n\u003cli\u003eComfortmaker\u003c\/li\u003e\n\u003cli\u003eArcoaire\u003c\/li\u003e\n\u003cli\u003eICP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible Furnace Models\u003c\/h2\u003e\n\u003cp\u003eThe 1172550 is listed for numerous furnace models, including:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eC8DNL Series:\u003c\/strong\u003e\u003cbr\u003eC8DNL050B12B1, C8DNL050B12B2, C8DNL075B12B1, C8DNL075B12B2, C8DNL075F16B1, C8DNL075F16B2, C8DNL100F14B1, C8DNL100F14B2, C8DNL100L20B1, C8DNL100L20B2, C8DNL125L20B1, C8DNL125L20B2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eC8MPL Series:\u003c\/strong\u003e\u003cbr\u003eC8MPL050B12B1, C8MPL050B12B2, C8MPL075B12B1, C8MPL075B12B2, C8MPL075F16B1, C8MPL075F16B2, C8MPL100F20B1, C8MPL100F20B2, C8MPL100J20B1, C8MPL100J20B2, C8MPL125J20B1, C8MPL125J20B2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eC8MPN Series:\u003c\/strong\u003e\u003cbr\u003eC8MPN050B12B1, C8MPN050B12B2, C8MPN075B12B1, C8MPN075B12B2, C8MPN075F16B1, C8MPN075F16B2, C8MPN100F14B1, C8MPN100F14B2, C8MPN100F20B1, C8MPN100F20B2, C8MPN100J20B1, C8MPN100J20B2, C8MPN125J20B1, C8MPN125J20B2, C8MPN150J20B1, C8MPN150J20B2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eC9MPD Series:\u003c\/strong\u003e\u003cbr\u003eC9MPD050F12C1, C9MPD050F12C2, C9MPD075F12C1, C9MPD075F12C2, C9MPD080J16C1, C9MPD080J16C2, C9MPD100J14C1, C9MPD100J14C2, C9MPD100J20C1, C9MPD100J20C2, C9MPD125L20C1, C9MPD125L20C2\u003c\/p\u003e\n\u003cp\u003eThe board is also listed across H8, H9, N8, N9, T8 and T9 series furnaces. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Symptoms of a Failed Furnace Control Board\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not start\u003c\/li\u003e\n\u003cli\u003eIgnitor will not energize\u003c\/li\u003e\n\u003cli\u003eInducer or blower does not operate correctly\u003c\/li\u003e\n\u003cli\u003eFurnace starts but fails to complete the heating cycle\u003c\/li\u003e\n\u003cli\u003eIntermittent furnace operation\u003c\/li\u003e\n\u003cli\u003eIncorrect blower operation\u003c\/li\u003e\n\u003cli\u003eFurnace displays control-board fault codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese symptoms can have causes other than the control board, so the furnace should be properly diagnosed before replacing the board.\u003c\/p\u003e\n\u003ch2\u003eICP 1172550 Replacement Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e1172550\u003c\/strong\u003e is a single-stage furnace control board used in a wide range of ICP equipment.\u003c\/p\u003e\n\u003cp\u003eWhen replacing a furnace control board, match the \u003cstrong\u003e1172550 part number\u003c\/strong\u003e and verify compatibility with the furnace model number before ordering.\u003c\/p\u003e\n\u003ch2\u003eBuy ICP 1172550 Furnace Control Board in Canada\u003c\/h2\u003e\n\u003cp\u003eBuy the \u003cstrong\u003eInternational Comfort Products 1172550 24V Single-Stage Furnace Control Board\u003c\/strong\u003e from \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eReplacement control board for select \u003cstrong\u003eICP, KeepRite, Heil, Tempstar, Comfortmaker and Arcoaire gas furnaces\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53716922433812,"sku":null,"price":600.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem1172550.jpg?v=1787668189"},{"product_id":"rheem-ruud-62-24084-82-protech-furnace-control-board","title":"Rheem Ruud 62-24084-82 ProTech Furnace Control Board","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 62-24084-82\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Rheem \/ Ruud ProTech\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Integrated Furnace Control Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Type:\u003c\/strong\u003e Hot Surface Ignition (HSI)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 1 Amp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Purge:\u003c\/strong\u003e 30 Seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Type:\u003c\/strong\u003e Natural Gas or LP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas Furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Gas valve, inducer motor, circulating blower and hot surface ignitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 62-24084-82 is designed for Rheem and Ruud furnaces equipped with hot surface ignition. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eReplacement \u0026amp; Cross-Reference Part Numbers\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRheem\/Ruud 62-24084-82\u003c\/strong\u003e replaces the following control boards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e62-22694-01\u003c\/li\u003e\n\u003cli\u003e62-22694-02\u003c\/li\u003e\n\u003cli\u003e62-22694-03\u003c\/li\u003e\n\u003cli\u003e62-22694-11\u003c\/li\u003e\n\u003cli\u003e62-22694-12\u003c\/li\u003e\n\u003cli\u003e62-22694-82\u003c\/li\u003e\n\u003cli\u003e62-22694-83\u003c\/li\u003e\n\u003cli\u003e62-22694-91\u003c\/li\u003e\n\u003cli\u003e62-22737-06\u003c\/li\u003e\n\u003cli\u003e62-22737-07\u003c\/li\u003e\n\u003cli\u003e62-22737-08\u003c\/li\u003e\n\u003cli\u003e62-22737-10\u003c\/li\u003e\n\u003cli\u003e62-22737-87\u003c\/li\u003e\n\u003cli\u003e62-22737-88\u003c\/li\u003e\n\u003cli\u003e62-24044-01\u003c\/li\u003e\n\u003cli\u003e62-24044-81\u003c\/li\u003e\n\u003cli\u003e62-24044-91\u003c\/li\u003e\n\u003cli\u003e62-24045-01\u003c\/li\u003e\n\u003cli\u003e62-24046-01\u003c\/li\u003e\n\u003cli\u003e62-24084-01\u003c\/li\u003e\n\u003cli\u003e62-24084-02\u003c\/li\u003e\n\u003cli\u003e62-24084-71\u003c\/li\u003e\n\u003cli\u003e62-24084-91\u003c\/li\u003e\n\u003cli\u003e62-24084-92\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese replacement numbers come directly from Rheem's documentation for the 62-24084-82. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eRheem 62-24084-82 Furnace Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRheem ProTech 62-24084-82\u003c\/strong\u003e is an integrated furnace control board used in select Rheem and Ruud gas furnaces with hot surface ignition.\u003c\/p\u003e\n\u003cp\u003eThe control board manages the furnace ignition sequence and operation of components including the \u003cstrong\u003einducer motor, hot surface ignitor, gas valve and circulating blower\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompatible Rheem \u0026amp; Ruud Furnace Series\u003c\/h2\u003e\n\u003cp\u003eThe 62-24084-82 is used with select furnace models from series including:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e90+ Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRGRA\u003c\/li\u003e\n\u003cli\u003eRGSA\u003c\/li\u003e\n\u003cli\u003eRGTA\u003c\/li\u003e\n\u003cli\u003eRGZC\u003c\/li\u003e\n\u003cli\u003eRGZD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e80+ Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRGDG\u003c\/li\u003e\n\u003cli\u003eRGDJ\u003c\/li\u003e\n\u003cli\u003eRGLG\u003c\/li\u003e\n\u003cli\u003eRGLH\u003c\/li\u003e\n\u003cli\u003eRGLJ\u003c\/li\u003e\n\u003cli\u003eRGPH\u003c\/li\u003e\n\u003cli\u003eRGPJ\u003c\/li\u003e\n\u003cli\u003eRGVG\u003c\/li\u003e\n\u003cli\u003eRGVH\u003c\/li\u003e\n\u003cli\u003eRGVJ\u003c\/li\u003e\n\u003cli\u003e80LJ\u003c\/li\u003e\n\u003cli\u003e80PJ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional Ruud equivalents include \u003cstrong\u003eUGDG, UGDJ, UGLG, UGLH, UGLJ, UGPH, UGPJ, UGRA, UGSA, UGTA, UGVG, UGVH and UGVJ\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eImportant Flame Sensor Information\u003c\/h2\u003e\n\u003cp\u003eSome older furnaces may also require the \u003cstrong\u003eRheem 62-24044-71 Flame Sensor Kit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eRheem specifically states that furnaces manufactured before date code \u003cstrong\u003e3294\u003c\/strong\u003e may require the addition of the 62-24044-71 flame sensor kit. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eHSI vs. DSI Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e62-24084-82 is for Hot Surface Ignition (HSI) systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eRheem states that furnaces equipped with \u003cstrong\u003eDirect Spark Ignition (DSI)\u003c\/strong\u003e require a different control board. Do not substitute the 62-24084-82 for a DSI control without confirming compatibility. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Symptoms of a Failed Furnace Control Board\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not start\u003c\/li\u003e\n\u003cli\u003eInducer motor does not energize\u003c\/li\u003e\n\u003cli\u003eHot surface ignitor does not energize\u003c\/li\u003e\n\u003cli\u003eGas valve does not receive power\u003c\/li\u003e\n\u003cli\u003eBlower does not operate correctly\u003c\/li\u003e\n\u003cli\u003eBlower runs continuously\u003c\/li\u003e\n\u003cli\u003eFurnace starts and then stops\u003c\/li\u003e\n\u003cli\u003eIntermittent furnace operation\u003c\/li\u003e\n\u003cli\u003eFurnace fails to complete the ignition sequence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOther furnace components can cause similar symptoms, so the control board should be properly diagnosed before replacement.\u003c\/p\u003e\n\u003ch2\u003eBuy Rheem 62-24084-82 Control Board in Canada\u003c\/h2\u003e\n\u003cp\u003eBuy the \u003cstrong\u003eRheem Ruud ProTech 62-24084-82 Integrated Furnace Control Board\u003c\/strong\u003e from \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53717651259668,"sku":null,"price":515.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem62-24084-82.jpg?v=1787682554"},{"product_id":"trane-cnt07941-120v-single-stage-furnace-control-board","title":"Trane CNT07941 120V Single-Stage Furnace Control Board","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e CNT07941\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Trane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Integrated Furnace \/ Ignition Control Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStages:\u003c\/strong\u003e Single Stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Hot Surface Ignition (HSI)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInducer Control:\u003c\/strong\u003e Single Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse:\u003c\/strong\u003e 5 Amp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas Furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Brands:\u003c\/strong\u003e Trane \/ American Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CNT07941 is designed for compatible \u003cstrong\u003e120V hot-surface ignition systems\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eReplacement \u0026amp; Cross-Reference Part Numbers\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTrane CNT07941\u003c\/strong\u003e replaces or cross-references with several older control-board numbers, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCNT07941\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT7941\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT-7941\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT07541\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT7541\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT-7541\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT03797\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT3797\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT-3797\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT02789\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT2789\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT-2789\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT03606\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCNT3606\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBAF00434\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBAF0434\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBAF-0434\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eD345780P01\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e50M56-495-04\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e50M5649504\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMultiple replacement-parts sources identify these older numbers with the CNT07941. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eTrane CNT07941 Furnace Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTrane CNT07941\u003c\/strong\u003e is a single-stage integrated furnace control board used in select Trane and American Standard gas furnaces.\u003c\/p\u003e\n\u003cp\u003eThe board controls the furnace ignition sequence and operation of components such as the \u003cstrong\u003ehot surface ignitor, gas valve, inducer and circulating blower\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is a replacement for several older Trane control boards, particularly \u003cstrong\u003eCNT07541, CNT03797 and BAF00434\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompatible Trane \u0026amp; American Standard Furnace Models\u003c\/h2\u003e\n\u003cp\u003eKnown applications include:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAUH1 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAUH1B040A9241AA\u003cbr\u003eAUH1B040A9241AB\u003cbr\u003eAUH1B060A9361AA\u003cbr\u003eAUH1B060A9361AB\u003cbr\u003eAUH1B080A9421AA\u003cbr\u003eAUH1B080A9421BA\u003cbr\u003eAUH1B080A9421BB\u003cbr\u003eAUH1C080A9601AA\u003cbr\u003eAUH1C100A9481AA\u003cbr\u003eAUH1D100A9601AA\u003cbr\u003eAUH1D120A9601AA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTUH1 Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTUH1B040A9241AA\u003cbr\u003eTUH1B040A9241AB\u003cbr\u003eTUH1B060A9361AA\u003cbr\u003eTUH1B060A9361AB\u003cbr\u003eTUH1B080A9421AA\u003cbr\u003eTUH1B080A9421BA\u003cbr\u003eTUH1B080A9421BB\u003cbr\u003eTUH1C080A9601AA\u003cbr\u003eTUH1C100A9481AA\u003cbr\u003eTUH1D100A9601AA\u003cbr\u003eTUH1D120A9601AA\u003c\/p\u003e\n\u003cp\u003eThese Trane and American Standard furnace applications are documented for the CNT07941. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Symptoms of a Failed Furnace Control Board\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not start\u003c\/li\u003e\n\u003cli\u003eHot surface ignitor does not energize\u003c\/li\u003e\n\u003cli\u003eInducer motor does not operate correctly\u003c\/li\u003e\n\u003cli\u003eGas valve does not receive power\u003c\/li\u003e\n\u003cli\u003eBlower motor does not operate correctly\u003c\/li\u003e\n\u003cli\u003eFurnace starts but does not complete the heating cycle\u003c\/li\u003e\n\u003cli\u003eIntermittent furnace operation\u003c\/li\u003e\n\u003cli\u003eControl board displays fault codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOther furnace components can cause similar symptoms, so the control board should be properly diagnosed before replacement.\u003c\/p\u003e\n\u003ch2\u003eCNT07541 Replacement Control Board\u003c\/h2\u003e\n\u003cp\u003eIf your existing Trane or American Standard furnace control board is marked \u003cstrong\u003eCNT07541 \/ CNT7541\u003c\/strong\u003e, the \u003cstrong\u003eCNT07941\u003c\/strong\u003e is listed as its replacement. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe CNT07941 also replaces several older board numbers, making those cross-reference numbers important when identifying the correct replacement.\u003c\/p\u003e\n\u003ch2\u003eBuy Trane CNT07941 Control Board in Canada\u003c\/h2\u003e\n\u003cp\u003eBuy the \u003cstrong\u003eTrane CNT07941 120V Single-Stage Furnace Control Board\u003c\/strong\u003e from \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003e\u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/a\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53718030582036,"sku":null,"price":350.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oemCNT07941.jpg?v=1787684389"},{"product_id":"carrier-hk32ea001-heat-pump-defrost-control-board","title":"Carrier HK32EA001 Heat Pump Defrost Control Board","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e HK32EA001\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Factory Authorized Parts™ \/ Carrier\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Defrost Control Board\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Heat Pumps\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eControl Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Time \/ Temperature Defrost Control\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDefrost Intervals:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30, 60 or 90 Minutes – Selectable\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDefrost Termination:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Defrost Thermostat or 10-Minute Maximum\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eSpeed-Up Test:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eApprovals:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CSA Listed\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eOEM Replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCarrier HK32EA001 Defrost Control Board\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCarrier HK32EA001 defrost control board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a Factory Authorized Parts™ replacement control used in select Carrier, Bryant and Payne heat pumps.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe HK32EA001 controls the heat pump defrost sequence during heating operation. When defrost is required, the board controls the reversing valve and outdoor fan to allow heat to remove frost and ice from the outdoor coil.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe board provides selectable \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e30, 60 and 90-minute defrost intervals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and works with the outdoor coil defrost thermostat to determine when the defrost cycle should begin and end.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Symptoms of a Failed HK32EA001 Defrost Board\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHeat pump will not enter defrost\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOutdoor coil becomes covered in frost or ice\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat pump remains in defrost\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOutdoor fan does not operate correctly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOutdoor fan continues running during defrost\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReversing valve does not switch during defrost\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntermittent defrost operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeat pump heating performance drops as outdoor coil freezes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBurned or damaged components on the control board\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBuy the Carrier HK32EA001 Heat Pump Defrost Control Board from OemHvacPartsCanada.ca.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53718488023316,"sku":null,"price":485.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oemHK32EA001.jpg?v=1787685672"},{"product_id":"lennox-59k21-lb-90403a-ahc1-2-control-board","title":"Lennox 59K21 \/ LB-90403A AHC1-2 Control Board","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e 59K21\u003cbr\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e LB-90403A\u003cbr\u003e\u003cstrong\u003eControl:\u003c\/strong\u003e AHC1-2\u003cbr\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Lennox\u003cbr\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e HVAC Control Board\u003cbr\u003e\u003cstrong\u003eLength:\u003c\/strong\u003e 5-1\/2\"\u003cbr\u003e\u003cstrong\u003eWidth:\u003c\/strong\u003e 8-1\/4\"\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Select Lennox, Armstrong, Allied, Concord and Ducane HVAC Equipment\u003cbr\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eReplaces\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e68K99\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e70J10\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e70J1001\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eLB-90847A\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eLB-90403A\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eLennox 59K21 \/ LB-90403A Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLennox 59K21 \/ LB-90403A AHC1-2 control board\u003c\/strong\u003e is used in select Lennox and Allied HVAC equipment. The board receives operating signals and controls equipment functions according to the system's operating sequence.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e59K21\u003c\/strong\u003e is found in a number of \u003cstrong\u003eAM30, AM61V and HM30 series\u003c\/strong\u003e units. Lennox parts documentation specifically identifies the 59K21 as the control board used in AM61V equipment. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCommon Symptoms of a Failed 59K21 Control Board\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC system will not start\u003c\/li\u003e\n\u003cli\u003eBlower motor will not operate\u003c\/li\u003e\n\u003cli\u003eBlower operates intermittently\u003c\/li\u003e\n\u003cli\u003eBlower runs continuously\u003c\/li\u003e\n\u003cli\u003eEquipment does not respond to thermostat calls\u003c\/li\u003e\n\u003cli\u003eIncorrect blower operation\u003c\/li\u003e\n\u003cli\u003eIntermittent system operation\u003c\/li\u003e\n\u003cli\u003eRelays on the board fail to energize\u003c\/li\u003e\n\u003cli\u003eBurned or damaged components on the board\u003c\/li\u003e\n\u003cli\u003eNo control output despite proper incoming power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuy the Lennox 59K21 \/ LB-90403A AHC1-2 Control Board from OemHvacPartsCanada.ca.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53720758419732,"sku":null,"price":265.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem59k21.jpg?v=1787751546"},{"product_id":"carrier-hh84aa017-blower-circuit-board","title":"Carrier HH84AA017 Blower Circuit Board","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e HH84AA017\u003cbr\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Carrier\u003cbr\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Blower Circuit Board\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Blower \/ Fan Control\u003cbr\u003e\u003cstrong\u003eBoard Dimensions:\u003c\/strong\u003e 5-3\/4\" x 4-1\/2\"\u003cbr\u003e\u003cstrong\u003eOEM Replacement:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003ch2\u003eModels That Use the HH84AA017\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHH84AA017 blower circuit board\u003c\/strong\u003e is used in many Carrier, Bryant and Payne packaged units, including:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e48NHT024-300BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NHT030-310BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NHT036-310BF\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NHT042-310BF\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NHT048-310BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NHT060-310BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NLT018-300BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NLT024-310BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NLT030-320BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NLT036-310BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NLT042-310BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NLT048-310BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e48NLT060-310BE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e580ANW024060AAAE\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e580ANW030080AAAF\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e580ANW036100AAAG\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e580ANW042100AAAG\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e580ANW048120AAAG\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e580ANW060120AAAR\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board is also used in additional \u003cstrong\u003e48NET, 48NEX, 48NHX, 48NLX, 48NMT, 48NMX, 48NVT, 580AEW, 580APW, 584AEW, 584ANW, 584APW and 587ANZ\u003c\/strong\u003e models. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSigns of a Faulty HH84AA017 Blower Board\u003c\/h2\u003e\n\u003cp\u003eA faulty \u003cstrong\u003eHH84AA017\u003c\/strong\u003e may cause the blower motor to not start, run continuously, operate intermittently or fail to shut off. Another sign is having the correct incoming power and control signal at the board but \u003cstrong\u003eno proper output from the board to the blower circuit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBurned relay contacts, damaged components or visible burn marks on the HH84AA017 can also indicate board failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuy the Carrier HH84AA017 Blower Circuit Board from \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/\"\u003eOemHvacPartsCanada.ca.\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53720862589204,"sku":null,"price":485.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oemHH84AA017.jpg?v=1787752135"},{"product_id":"carrier-325879-751-furnace-control-board-kit","title":"Carrier 325879-751 Furnace Control Board Kit","description":"\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 325879-751\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eType:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Integrated Furnace Control Board Kit\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStages:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Two-Stage\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIgnition Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Hot Surface Ignition (HSI)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIgnition Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 120 VAC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Gas Furnace\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBrands:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Carrier, Bryant \u0026amp; Payne\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReplacement Board:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e HK42FZ017\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eKit Includes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Control board, wiring harness adapter and installation instructions\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eControls:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Gas valve, igniter, blower motor, inducer motor, humidifier and electronic air cleaner\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDiagnostic LED:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTwinning Compatible:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eReplaces\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHK42FZ005\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHK42FZ010\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHK42FZ015\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHK42FZ017\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWhite-Rodgers 21V51D-751\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eICM2807\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e are also listed as replacements for the 325879-751.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFurnace Series\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 325879-751 is used in Carrier\/Bryant furnace series including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e58UXV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e352MAV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e330JAV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58TMA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e331AAV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58SUA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e333BAV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e333JAV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e330AAV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58TUA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58DXT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58UHV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58UXT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGB1AAV\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFurnace Models\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKnown compatible Carrier models include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e58MTA060F10112\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58MTA080F10112\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58MTA080-F\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58MTA100F10116\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58MTA100F10120\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58MTA120F10120\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58MCA080-14\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58MCA100-16\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e58MSA060-12\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAdditional compatible equipment includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBryant 310AAV042090\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePayne PG8UAA048080\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSymptoms of a Failing Furnace Control Board\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFurnace will not start\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e even though power is present.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBurners will not ignite\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e or fail to stay lit.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eBlower motor does not start.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBlower runs continuously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e even when there is no call for heat.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInducer motor does not receive power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e during the heating sequence.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eFurnace starts and then shuts down.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIntermittent heating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e or unpredictable furnace operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eFurnace short cycles.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNo power being sent to the gas valve or igniter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when it should be energized.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eIncorrect or missing diagnostic LED operation.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese symptoms can also be caused by other furnace components, so the board should be properly diagnosed before replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBuy in Canada\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBuy the Carrier 325879-751 Furnace \u003ca href=\"https:\/\/oemhvacpartscanada.ca\/collections\/board\"\u003eControl Board\u003c\/a\u003e Kit at \u003ca href=\"https:\/\/oemhvacpartscanada.ca\"\u003eOemHvacPartsCanada.ca.\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53725126590740,"sku":null,"price":1500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem325879-751.jpg?v=1787784549"},{"product_id":"nordyne-903429-integrated-furnace-control-board-m1-series","title":"Nordyne 903429 Integrated Furnace Control Board – M1 Series","description":"\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 903429\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Nordyne \/ Nortek\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Integrated Furnace Control Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Gas \/ Oil Furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFurnace Series:\u003c\/strong\u003e M1 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 120 VAC, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 18–30 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Hot Surface Ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part:\u003c\/strong\u003e 903429\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Replacement:\u003c\/strong\u003e 903429A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003e903429\u003c\/strong\u003e is an integrated furnace control used in Nordyne M1-series equipment. The original 903429 has been discontinued and is now replaced by \u003cstrong\u003e903429A\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eReplacement \u0026amp; Cross-Reference Part Numbers\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e903429 \/ 903429A\u003c\/strong\u003e replaces or cross-references with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e903429\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e903429A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e624602\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e6246020\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e624602-0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e624602A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e624602B\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e624640\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e624640-A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1012-93-9581A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1012-012-958A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e233089\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eICM specifically lists \u003cstrong\u003e903429, 624602, 624640, 1012-93-9581A, 1012-012-958A and 233089\u003c\/strong\u003e as boards replaced by its ICM2818 Nordyne replacement control. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eNordyne 903429 Furnace Control Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNordyne 903429\u003c\/strong\u003e is an integrated furnace control board used in select \u003cstrong\u003eNordyne, Miller and Intertherm M1-series furnaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe control board manages the furnace operating sequence, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInduced draft blower\u003c\/li\u003e\n\u003cli\u003eCirculating blower\u003c\/li\u003e\n\u003cli\u003eHot surface ignitor\u003c\/li\u003e\n\u003cli\u003eGas valve\u003c\/li\u003e\n\u003cli\u003eFlame sensing\u003c\/li\u003e\n\u003cli\u003eFurnace safety monitoring\u003c\/li\u003e\n\u003cli\u003eDiagnostic fault operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe board receives thermostat and furnace safety inputs and controls the appropriate components throughout the heating cycle. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eCompatible Furnace Series\u003c\/h2\u003e\n\u003cp\u003eThe 903429 is documented for \u003cstrong\u003eM1 Series\u003c\/strong\u003e furnaces, including \u003cstrong\u003eM1M-A\/B\/C\/D\u003c\/strong\u003e applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eKnown compatible models include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eM1MA056AAW\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM1MA056ABW\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM1MA070AAW\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM1MA070ABW\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM1MB056AAW\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM1MB090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM1MD090\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM1MAH070\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eParts data specifically identifies these as applications for the 903429 control. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e903429A Replacement for 903429\u003c\/h2\u003e\n\u003cp\u003eThe original \u003cstrong\u003eNordyne 903429 has been discontinued\u003c\/strong\u003e. The direct replacement is \u003cstrong\u003e903429A\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe newer \u003cstrong\u003e903429A version requires a flame sensor to be added\u003c\/strong\u003e, and replacement kits may include the required flame sensor. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis is an important distinction when replacing an older 903429 board.\u003c\/p\u003e\n\u003ch2\u003eCommon Symptoms of a Failed Furnace Control Board\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not start\u003c\/li\u003e\n\u003cli\u003eInducer motor does not energize\u003c\/li\u003e\n\u003cli\u003eHot surface ignitor does not energize\u003c\/li\u003e\n\u003cli\u003eGas valve does not receive power\u003c\/li\u003e\n\u003cli\u003eCirculating blower does not operate\u003c\/li\u003e\n\u003cli\u003eBlower runs continuously\u003c\/li\u003e\n\u003cli\u003eFurnace starts and then shuts down\u003c\/li\u003e\n\u003cli\u003eIntermittent furnace operation\u003c\/li\u003e\n\u003cli\u003eFurnace goes into safety lockout\u003c\/li\u003e\n\u003cli\u003eControl board does not properly sequence furnace operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOther furnace components can produce similar symptoms, so the control board should be properly diagnosed before replacement.\u003c\/p\u003e\n\u003ch2\u003eBuy Nordyne 903429 \/ 903429A Control Board in Canada\u003c\/h2\u003e\n\u003cp\u003eBuy the \u003cstrong\u003eNordyne 903429 \/ 903429A Integrated Furnace Control Board\u003c\/strong\u003e from \u003cstrong\u003eOemHvacPartsCanada.ca\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Oem Hvac Parts Canada","offers":[{"title":"Default Title","offer_id":53736320696596,"sku":null,"price":500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/6146\/6132\/files\/oem903429.jpg?v=1787956200"}],"url":"https:\/\/oemhvacpartscanada.ca\/collections\/board.oembed?page=2","provider":"Oem Hvac Parts Canada","version":"1.0","type":"link"}